The Visiopharm human epidermal growth factor receptor 2 (HER2) digital imaging analysis (DIA) algorithm assesses digitized HER2 immunohistochemistry (IHC) by measuring cell membrane connectivity. We aimed to validate this algorithm for clinical use by comparing with pathologists' scoring and correlating with HER2 fluorescence hybridization (FISH) results.
The study cohort consisted of 612 consecutive invasive breast carcinoma specimens including 395 biopsies and 217 resections. HER2 IHC slides were scanned using Philips IntelliSite Scanners, and the digital images were analyzed using Visiopharm HER2-CONNECT App to obtain the connectivity values (0-1) and scores (0, 1+, 2+, and 3+). HER2 DIA scores were compared with Pathologists' manual scores, and HER2 connectivity values were correlated with FISH results.
The concordance between HER2 DIA scores and pathologists' scores was 87.3% (534/612). All discordant cases ( = 78) were only one-step discordant (negative to equivocal, equivocal to positive, or vice versa). Five cases (0.8%) showed discordant HER2 IHC DIA and FISH results, but all these cases had relatively low copy numbers (between 4 and 6). HER2 IHC connectivity showed significantly better correlation with copy number than ratio.
HER2 IHC DIA demonstrates excellent concordance with pathologists' scores and accurately discriminates between FISH positive and negative cases. HER2 IHC connectivity has better correlation with copy number than ratio, suggesting copy number may be more important in predicting HER2 protein expression, and response to anti-HER2-targeted therapy.
Visiopharm人表皮生长因子受体2(HER2)数字成像分析(DIA)算法通过测量细胞膜连通性来评估数字化HER2免疫组织化学(IHC)。我们旨在通过与病理学家评分进行比较并与HER2荧光原位杂交(FISH)结果相关联,来验证该算法在临床中的应用。
研究队列包括612例连续的浸润性乳腺癌标本,其中395例为活检标本,217例为切除标本。使用飞利浦IntelliSite扫描仪对HER2 IHC载玻片进行扫描,并使用Visiopharm HER2-CONNECT应用程序分析数字图像,以获得连通性值(0-1)和评分(0、1+、2+和3+)。将HER2 DIA评分与病理学家的手动评分进行比较,并将HER2连通性值与FISH结果相关联。
HER2 DIA评分与病理学家评分之间的一致性为87.3%(534/612)。所有不一致的病例(n = 78)仅相差一个等级(阴性至可疑、可疑至阳性或反之亦然)。5例(0.8%)显示HER2 IHC DIA与FISH结果不一致,但所有这些病例的拷贝数相对较低(4至6之间)。HER2 IHC连通性与拷贝数的相关性明显优于与比值的相关性。
HER2 IHC DIA与病理学家评分具有极好的一致性,并能准确区分FISH阳性和阴性病例。HER2 IHC连通性与拷贝数的相关性优于与比值的相关性,这表明拷贝数在预测HER2蛋白表达及抗HER2靶向治疗反应方面可能更为重要。