Chen Terry Yuan-Fang, Chou Yun-Chia, Wang Zhao-Ying, Lin Wen-Yen, Lin Ming-Tzer
Department of Mechanical Engineering, National Cheng Kung University, Tainan 701, Taiwan.
Graduate Institute of Precision Engineering, National Chung Hsing University, Taichung 402, Taiwan.
Materials (Basel). 2020 Mar 12;13(6):1291. doi: 10.3390/ma13061291.
The residual stress of thin films during the deposition process can cause the components to have unpredictable deformation and damage, which could affect the service life and reliability of the microsystems. Developing an accurate and reliable method for measuring the residual stress of thin films at the micrometer and nanometer scale is a great challenge. To analyze the residual stress regarding factors such as the mechanical anisotropy and preferred orientation of the materials, information related to the in-depth lattice strain function is required when calculating the depth profiles of the residual strain. For depth-resolved measurements of residual stress, it is strategically advantageous to develop a measurement procedure that is microstructurally independent. Here, by performing an incremental focused ion beam (FIB) ring-core drilling experiment with various depth steps, the digital image correlation (DIC) of the specimen images was obtained. The feasibility of DIC to FIB images was evaluated after the translation test, and an appropriate procedure for reliable results was established. Furthermore, the condition of the film in the function of residual stress was assessed and compared to elucidate the applicability of this technology.
薄膜在沉积过程中的残余应力会导致部件产生不可预测的变形和损坏,这可能会影响微系统的使用寿命和可靠性。开发一种准确可靠的方法来测量微米和纳米尺度薄膜的残余应力是一项巨大的挑战。为了分析与材料的机械各向异性和择优取向等因素相关的残余应力,在计算残余应变的深度分布时,需要与深度晶格应变函数相关的信息。对于残余应力的深度分辨测量,开发一种与微观结构无关的测量程序具有战略优势。在此,通过进行具有不同深度步长的增量聚焦离子束(FIB)环形芯钻孔实验,获得了试样图像的数字图像相关(DIC)结果。在平移测试后评估了DIC用于FIB图像的可行性,并建立了获得可靠结果的适当程序。此外,评估并比较了薄膜在残余应力作用下的状态,以阐明该技术的适用性。