Radboud University Medical Center, 6525, GA, Nijmegen, The Netherlands.
Community Health Solutions, Karachi, 74000, Pakistan.
Sci Rep. 2020 Mar 26;10(1):5492. doi: 10.1038/s41598-020-62148-y.
There is a growing interest in the automated analysis of chest X-Ray (CXR) as a sensitive and inexpensive means of screening susceptible populations for pulmonary tuberculosis. In this work we evaluate the latest version of CAD4TB, a commercial software platform designed for this purpose. Version 6 of CAD4TB was released in 2018 and is here tested on a fully independent dataset of 5565 CXR images with GeneXpert (Xpert) sputum test results available (854 Xpert positive subjects). A subset of 500 subjects (50% Xpert positive) was reviewed and annotated by 5 expert observers independently to obtain a radiological reference standard. The latest version of CAD4TB is found to outperform all previous versions in terms of area under receiver operating curve (ROC) with respect to both Xpert and radiological reference standards. Improvements with respect to Xpert are most apparent at high sensitivity levels with a specificity of 76% obtained at a fixed 90% sensitivity. When compared with the radiological reference standard, CAD4TB v6 also outperformed previous versions by a considerable margin and achieved 98% specificity at the 90% sensitivity setting. No substantial difference was found between the performance of CAD4TB v6 and any of the various expert observers against the Xpert reference standard. A cost and efficiency analysis on this dataset demonstrates that in a standard clinical situation, operating at 90% sensitivity, users of CAD4TB v6 can process 132 subjects per day at an average cost per screen of $5.95 per subject, while users of version 3 process only 85 subjects per day at a cost of $8.38 per subject. At all tested operating points version 6 is shown to be more efficient and cost effective than any other version.
人们对使用计算机辅助分析(CAD)自动分析胸部 X 光(CXR)越来越感兴趣,因为这是一种敏感且廉价的方法,可用于对易感染人群进行肺结核筛查。在这项工作中,我们评估了 CAD4TB 的最新版本,这是一款专为该目的设计的商业软件平台。CAD4TB 的 6 版本于 2018 年发布,现已在一个包含 5565 张 CXR 图像的完全独立数据集上进行了测试,这些图像都具有 GeneXpert(Xpert)痰检测结果(854 例 Xpert 阳性病例)。选择其中的 500 例(50% Xpert 阳性)病例,由 5 位专家观察者进行回顾和独立注释,以获得放射学参考标准。最新版本的 CAD4TB 在与 Xpert 和放射学参考标准相关的受试者工作特征(ROC)曲线下面积方面优于所有以前的版本。与 Xpert 相比,灵敏度为 90%时,特异性为 76%时,灵敏度提高最为明显。与放射学参考标准相比,CAD4TB v6 的性能也有了相当大的提高,在灵敏度为 90%的设置下,特异性达到 98%。CAD4TB v6 的性能与 Xpert 参考标准下的任何一位专家观察者之间没有发现实质性差异。对该数据集的成本和效率分析表明,在标准临床情况下,以 90%的灵敏度运行时,CAD4TB v6 的用户每天可以处理 132 名患者,每位患者的平均屏幕成本为 5.95 美元,而版本 3 的用户每天只能处理 85 名患者,每位患者的成本为 8.38 美元。在所有测试的工作点上,与其他任何版本相比,版本 6 都显示出更高的效率和成本效益。