Suppr超能文献

30-15 间歇性体能测试的重测信度:系统评价。

Test-retest reliability of the 30-15 Intermittent Fitness Test: A systematic review.

机构信息

Institute for Health and Sport (IHES), Victoria University, Melbourne, VIC 3011, Australia.

Faculty of Education, Department of Kinesiology, J.J. Strossmayer University, Osijek 31000, Croatia.

出版信息

J Sport Health Sci. 2021 Jul;10(4):413-418. doi: 10.1016/j.jshs.2020.04.010. Epub 2020 May 15.

Abstract

PURPOSE

This review aimed to synthesize previous findings on the test-retest reliability of the 30-15 Intermittent Fitness Test (IFT).

METHODS

The literature searches were performed in 8 databases. Studies that examined the test-retest reliability of the 30-15 IFT and presented the intraclass correlation coefficient (ICC) and/or the coefficient of variation (CV) for maximal velocity and/or peak heart rate were included. The consensus-based standards for the selection of health measurement instruments (COSMIN) checklist was used for the assessment of the methodological quality of the included studies.

RESULTS

Seven studies, with a total of 10 study groups, explored reliability of maximal velocity assessed by the 30-15 IFT. ICCs ranged from 0.80 to 0.99, where 70% of ICCs were ≥0.90. CVs for maximal velocity ranged from 1.5% to 6.0%. Six studies, with a total of 7 study groups, explored reliability of peak heart rate as assessed by the 30-15 IFT. ICCs ranged from 0.90 to 0.97 (i.e., all ICCs were ≥0.90). CVs ranged from 0.6% to 4.8%. All included studies were of excellent methodological quality.

CONCLUSION

From the results of this systematic review, it can be concluded that the 30-15 IFT has excellent test-retest reliability for both maximal velocity and peak heart rate. The test may, therefore, be used as a reliable measure of fitness in research and sports practice.

摘要

目的

本综述旨在综合之前关于 30-15 间歇性健身测试(IFT)重测信度的研究结果。

方法

在 8 个数据库中进行文献检索。纳入研究检验了 30-15 IFT 的重测信度,并报告了最大速度和/或最大心率的组内相关系数(ICC)和/或变异系数(CV)。采用基于共识的健康测量仪器选择标准(COSMIN)检查表评估纳入研究的方法学质量。

结果

7 项研究(共 10 个研究组)探讨了 30-15 IFT 评估的最大速度的可靠性。ICC 范围为 0.80 至 0.99,其中 70%的 ICC 值≥0.90。最大速度的 CV 值范围为 1.5%至 6.0%。6 项研究(共 7 个研究组)探讨了 30-15 IFT 评估的最大心率的可靠性。ICC 范围为 0.90 至 0.97(即所有 ICC 值均≥0.90)。CV 值范围为 0.6%至 4.8%。所有纳入的研究均具有极好的方法学质量。

结论

根据本系统综述的结果,可以得出结论,30-15 IFT 对于最大速度和最大心率均具有极好的重测信度。因此,该测试可用于研究和体育实践中作为可靠的健康指标。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/9887/8343059/af50cd4dfe29/fx1.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验