Department of Preventive Dental Sciences, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia.
General Dentist, Cosmoline Medical Center, Abha, Saudi Arabia.
Arch Oral Biol. 2020 Jul;115:104714. doi: 10.1016/j.archoralbio.2020.104714. Epub 2020 Apr 11.
The aim of the present observational case-control study was to compare the levels of Receptor activator of NF-kappa B ligand (RANKL) and osteoprotegerin (OPG) in the gingival crevicular fluid (GCF) of cigarette- and waterpipe-smokers and electronic-nicotine-delivery-systems (ENDS)-users.
Demographic data was collected using a questionnaire. Clinical periodontal parameters (plaque index [PI], bleeding on probing [BOP], probing depth [PD] and clinical attachment loss [CAL]) were measured; and GCF samples were collected from the deepest periodontal pocket of the mandibular right first molar. The GCF volume was determined and levels of RANKL and OPG were determined. Group comparisons were performed and P < 0.05 was considered statistically significant.
One hundred and twenty male individuals (30 cigarette-smokers, 30 waterpipe users, 30 ENDS-users and 30 non-smokers) were included. Scores of PI (P < 0.01) and PD (P < 0.01) were significantly higher among cigarette- and waterpipe smokers, and ENDS-users than non-smokers. The GCF volume was significantly higher among cigarette- (0.92 ± 0.05 μl) (P < 0.01) and waterpipe-smokers (0.66 ± 0.08 μl) (P < 0.001) and ENDS-users (0.62 ± 0.03 μl) (P < 0.01) than non-smokers (0.21 ± 0.007 μl). The GCF RANKL levels were significantly higher among cigarette- (14.9 ± 8.2 pg/ml) (P < 0.001) and waterpipe-smokers (12.6 ± 8.8 pg/ml) (P < 0.01) and ENDS-users (11.5 ± 8.4 pg/ml) (P < 0.01) than non-smokers (3.5 ± 0.7 pg/ml). The GCF OPG levels were significantly higher among cigarette- (95.9 ± 7.2 pg/ml) (P < 0.001) and waterpipe-smokers (86.6 ± 5.8 pg/ml) (P < 0.01) and ENDS-users (77.5 ± 3.4 pg/ml) (P < 0.05) than non-smokers (21.5 ± 10.7 pg/ml). There was no significant difference in GCF RANKL and OPG levels among cigarette- and waterpipe smokers, ENDS users.
Cigarette- and waterpipe smoking and ENDS usage is associated with an increased expression of RANKL and OPG in the GCF.
本观察性病例对照研究的目的是比较香烟、水烟和电子烟使用者龈沟液(GCF)中核因子-κB 受体激活配体(RANKL)和骨保护素(OPG)的水平。
使用问卷收集人口统计学数据。测量临床牙周参数(菌斑指数[PI]、探诊出血[BOP]、探诊深度[PD]和临床附着丧失[CAL]);并从下颌右侧第一磨牙的最深牙周袋中采集 GCF 样本。确定 GCF 体积并确定 RANKL 和 OPG 水平。进行组间比较,P 值<0.05 被认为具有统计学意义。
共纳入 120 名男性个体(30 名香烟吸烟者、30 名水烟使用者、30 名电子烟使用者和 30 名不吸烟者)。香烟和水烟吸烟者以及电子烟使用者的 PI 评分(P<0.01)和 PD 评分(P<0.01)明显更高。香烟(0.92±0.05 μl)(P<0.01)和水烟吸烟者(0.66±0.08 μl)(P<0.001)以及电子烟使用者(0.62±0.03 μl)(P<0.01)的 GCF 体积明显高于不吸烟者(0.21±0.007 μl)。香烟(14.9±8.2 pg/ml)(P<0.001)和水烟吸烟者(12.6±8.8 pg/ml)(P<0.01)以及电子烟使用者(11.5±8.4 pg/ml)(P<0.01)的 GCF RANKL 水平明显高于不吸烟者(3.5±0.7 pg/ml)。香烟(95.9±7.2 pg/ml)(P<0.001)和水烟吸烟者(86.6±5.8 pg/ml)(P<0.01)以及电子烟使用者(77.5±3.4 pg/ml)(P<0.05)的 GCF OPG 水平明显高于不吸烟者(21.5±10.7 pg/ml)。香烟和水烟吸烟者以及电子烟使用者的 GCF RANKL 和 OPG 水平无显著差异。
香烟和水烟吸烟以及电子烟使用与 GCF 中 RANKL 和 OPG 的表达增加有关。