Abstract

PURPOSE

External beam radiotherapy is one of the treatment options for organ-confined prostate cancer. A total dose of 70 to 81 Gray (Gy) is given daily (1.8-2.5 Gy/d), with a dose rate of 3 to 6 Gy/min over 28 to 45 treatments during 8 to 9 weeks. We applied the latest technological development in linear accelerators for enabling a wide range of dose rates (from 0.2-21 Gy/min) to test the effect of different delivery dose rates on prostate tumor growth in an animal xenograft model.

MATERIALS AND METHODS

A prostate cancer xenograft model was established in CD1/nude mice by means of PC-3 and CL-1 cells. The animals were radiated by a TrueBeam linear accelerator that delivered 4 dose rates ranging from 0.6 to 14 Gy/min, and reaching a total dose of 20 Gy. The mice were weighed and monitored for tumor development twice weekly. A 2-way analysis of variance was used to compare statistical differences between the groups.

RESULTS

Tumor growth was inhibited by radiation at all 4 dose rates in the 20 study mice compared to no radiation (n = 5, controls). The most significant reduction in tumor volumes was observed when the same dose of radiation was delivered at a rate of 0.6 Gy/min ( < .01). The animals' weights were not affected by any dose rate.

CONCLUSIONS

Delivery of radiation with a TrueBeam linear accelerator at the lowest possible rate was most effective in prostate cancer growth inhibition and might be considered a preferential treatment mode for localized prostate cancer.

摘要

目的

外照射放疗是治疗局限性前列腺癌的方法之一。每天给予总剂量 70 至 81 戈瑞(Gy),剂量率为 3 至 6 Gy/min,28 至 45 次治疗,持续 8 至 9 周。我们应用直线加速器的最新技术发展,实现了广泛的剂量率(0.2-21 Gy/min),以测试不同的治疗剂量率对动物异种移植模型中前列腺肿瘤生长的影响。

材料和方法

通过 PC-3 和 CL-1 细胞在 CD1/ nude 小鼠中建立前列腺癌异种移植模型。动物用 TrueBeam 直线加速器进行放射治疗,该加速器提供 4 种剂量率,范围从 0.6 至 14 Gy/min,总剂量为 20 Gy。每周两次称重并监测肿瘤进展情况。采用双向方差分析比较组间的统计学差异。

结果

与未接受辐射的对照组(n = 5)相比,20 只研究小鼠在 4 种剂量率的辐射下,肿瘤生长均受到抑制。当以 0.6 Gy/min 的相同剂量进行辐射时,肿瘤体积的减少最为显著(<0.01)。任何剂量率均未影响动物的体重。

结论

使用 TrueBeam 直线加速器以尽可能低的剂量率进行放射治疗,在抑制前列腺癌生长方面最为有效,可能被视为局限性前列腺癌的首选治疗模式。