Moon Hyun-Soo, Choi Chong-Hyuk, Jung Min, Lee Dae-Young, Kim Jung-Hwan, Kim Sung-Hwan
Arthroscopy and Joint Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea.
Department of Orthopedic Surgery, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang, Republic of Korea.
BMC Musculoskelet Disord. 2020 Jul 17;21(1):470. doi: 10.1186/s12891-020-03487-9.
Although the measurement of coronal alignment of the lower limb on conventional full-length weight-bearing anteroposterior (FLWAP) radiographs was reported to be influenced by the knee joint rotation, no comparative analysis was performed considering the effects of knee joint rotation on the sagittal and axial planes simultaneously using the three-dimensional images while taking into account the actual weight-bearing conditions. The aim of this study was to investigate the effect of knee joint rotation on the measurement accuracy of coronal alignment of the lower limb on the FLWAP radiograph.
Radiographic images of 90 consecutive patients (180 lower limbs) who took both the FLWAP radiograph and the EOS image were retrospectively reviewed. The relationship among delta values of mechanical tibiofemoral angle (mTFA) between the FLWAP radiographs and the EOS images (ΔmTFA), knee flexion/extension angle (sagittal plane rotation) on the EOS images, and patellar rotation (axial plane rotation) on the FLWAP radiographs were analyzed. Further, subgroup analysis according to each direction of knee joint rotation was performed.
There was a significant correlation between ΔmTFA and sagittal plane rotation (r = 0.368, P < 0.001), whereas axial plane rotation was not correlated. In the analysis according to the direction, statistically significant correlation was observed only in the knee flexion group (r = 0.399, P < 0.001). The regression analysis showed a significant linear relationship between ΔmTFA and sagittal plane rotation (r = 0.136, P < 0.001). Additional subgroup analysis in patients with the patellar rotation greater than 3% showed a similar result of a linear relationship between ΔmTFA and sagittal plane rotation (r = 0.257, P < 0.001), whereas no statistically significant relationship was found in patients with the patellar rotation less than 3%.
The measurement accuracy of coronal alignment of the lower limb on the FLWAP radiographs would be influenced by knee flexion, specifically when there is any subtle rotation of the knee joint in the axial plane. A strict patellar forward position without axial plane rotation of the knee could provide accurate results of the measurement even if there is a fixed flexion contracture of the knee.
尽管据报道,在传统的全长负重前后位(FLWAP)X线片上测量下肢冠状面力线会受到膝关节旋转的影响,但尚未在考虑实际负重情况的同时,使用三维图像对膝关节旋转在矢状面和轴面的影响进行比较分析。本研究的目的是探讨膝关节旋转对FLWAP X线片上下肢冠状面力线测量准确性的影响。
回顾性分析90例连续患者(180条下肢)的X线图像,这些患者同时拍摄了FLWAP X线片和EOS图像。分析了FLWAP X线片与EOS图像之间机械性胫股角(mTFA)的差值(ΔmTFA)、EOS图像上的膝关节屈伸角度(矢状面旋转)以及FLWAP X线片上的髌骨旋转(轴面旋转)之间的关系。此外,根据膝关节旋转的每个方向进行了亚组分析。
ΔmTFA与矢状面旋转之间存在显著相关性(r = 0.368,P < 0.001),而与轴面旋转无相关性。在按方向进行的分析中,仅在膝关节屈曲组观察到统计学上的显著相关性(r = 0.399,P < 0.001)。回归分析显示ΔmTFA与矢状面旋转之间存在显著的线性关系(r = 0.136,P < 0.001)。对髌骨旋转大于3%的患者进行的额外亚组分析显示,ΔmTFA与矢状面旋转之间存在类似的线性关系(r = 0.257,P < 0.001),而在髌骨旋转小于3%的患者中未发现统计学上的显著关系。
FLWAP X线片上下肢冠状面力线的测量准确性会受到膝关节屈曲的影响,特别是当膝关节在轴面有任何细微旋转时。即使膝关节存在固定的屈曲挛缩,严格的髌骨向前位置且膝关节无轴面旋转也能提供准确的测量结果。