Suppr超能文献

用于测定人唾液中硝酸盐和亚硝酸盐的新型微流控纸基分析装置(μPADs)。

Novel microfluidic paper-based analytical devices (μPADs) for the determination of nitrate and nitrite in human saliva.

作者信息

Ferreira Francisca T S M, Mesquita Raquel B R, Rangel António O S S

机构信息

Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho 1327, 4169-005, Porto, Portugal.

Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho 1327, 4169-005, Porto, Portugal.

出版信息

Talanta. 2020 Nov 1;219:121183. doi: 10.1016/j.talanta.2020.121183. Epub 2020 May 27.

Abstract

In this work, two different microfluidic paper-based analytical devices (μPADs) were developed for the quantification of nitrite and nitrate in human saliva samples, in order to aid in the diagnosis of some diseases and health conditions associated with these ions. The development of these nitrite and nitrate μPADs involved several studies to optimize their design and construction, including an interference assessment and stability studies. These μPADs allowed a nitrite determination in a range of 5-250 μM with limits of detection and quantification of 0.05 μM and 0.17 μM, respectively, and a nitrate determination in the range 0.2-1.2 mM with limits of detection and quantification of 0.08 mM and 0.27 mM, respectively. As for the stability, both of the μPADs were stable when stored in vacuum at 4 °C (the nitrite μPAD for at least 60 days and the nitrate μPAD for at least of 14 days) and, after the sample placement, the nitrite and nitrate μPADs could be scanned within the first 4 and 2 h, respectively. The nitrite μPAD measurements were compared with the ones obtained from the standard colorimetric method and there were no statistically significant differences between these two methods. To evaluate the accuracy of nitrate μPAD measurements, 4 certified water samples were used and recovery studies using saliva samples were performed.

摘要

在这项工作中,开发了两种不同的基于微流控纸的分析装置(μPADs),用于定量测定人类唾液样本中的亚硝酸盐和硝酸盐,以辅助诊断与这些离子相关的一些疾病和健康状况。这些亚硝酸盐和硝酸盐μPADs的开发涉及多项研究,以优化其设计和构建,包括干扰评估和稳定性研究。这些μPADs能够测定浓度范围为5 - 250μM的亚硝酸盐,其检测限和定量限分别为0.05μM和0.17μM,以及测定浓度范围为0.2 - 1.2 mM的硝酸盐,其检测限和定量限分别为0.08 mM和0.27 mM。至于稳定性,两种μPADs在4℃真空储存时都很稳定(亚硝酸盐μPAD至少稳定60天,硝酸盐μPAD至少稳定14天),并且在放置样品后,亚硝酸盐和硝酸盐μPADs分别可在最初4小时和2小时内进行扫描。将亚硝酸盐μPAD的测量结果与通过标准比色法获得的结果进行比较,这两种方法之间没有统计学上的显著差异。为了评估硝酸盐μPAD测量的准确性,使用了4个经过认证的水样,并对唾液样本进行了回收率研究。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验