Suppr超能文献

不同阶段糖尿病视网膜病变患者的静态和动态瞳孔反应

Static and Dynamic Pupillary Responses in Patients with Different Stages of Diabetic Retinopathy.

作者信息

Kızıltoprak Hasan, Tekin Kemal, Sekeroglu Mehmet Ali, Yetkin Esat, Doguizi Sibel, Yilmazbas Pelin

机构信息

Ophthalmology Department, Bingol Women's Health and Children's Hospital, Bingol, Turkey.

Ophthalmology Department, Ercis State Hospital, Van, Turkey.

出版信息

Neuroophthalmology. 2019 Nov 25;44(4):226-235. doi: 10.1080/01658107.2019.1671465. eCollection 2020.

Abstract

This study aimed to investigate pupillary involvement in patients with type 2 diabetes mellitus (DM) and to evaluate whether there is a relationship between severity of diabetic retinopathy (DR) and pupillary responses. The study included 133 individuals in four groups: proliferative DR, non-proliferative DR, DM group without retinal involvement and a control group. Static pupillometry measurements including scotopic pupil diameter (PD), mesopic PD, low photopic PD, high photopic PD, and dynamic pupillometry measurements, including resting diameter, amplitude, latency, velocity, duration of pupil contraction and latency, duration, and velocity of pupil dilatation were taken using an automated quantitative pupillometry system. The correlations between glycosylated haemoglobin values and duration of DM with these parameters were also investigated. The study showed that patients with DR may also have diabetic autonomic neuropathy and pupillometry can be a useful screening tool for detecting diabetic autonomic neuropathy.

摘要

本研究旨在调查2型糖尿病(DM)患者的瞳孔受累情况,并评估糖尿病视网膜病变(DR)的严重程度与瞳孔反应之间是否存在关联。该研究纳入了四组共133名个体:增殖性DR组、非增殖性DR组、无视网膜受累的DM组和对照组。使用自动定量瞳孔测量系统进行静态瞳孔测量,包括暗视瞳孔直径(PD)、中间视PD、低明视PD、高明视PD,以及动态瞳孔测量,包括静息直径、幅度、潜伏期、速度、瞳孔收缩持续时间以及瞳孔扩张的潜伏期、持续时间和速度。还研究了糖化血红蛋白值和DM病程与这些参数之间的相关性。研究表明,DR患者可能也存在糖尿病自主神经病变,瞳孔测量可作为检测糖尿病自主神经病变的有用筛查工具。

相似文献

1
Static and Dynamic Pupillary Responses in Patients with Different Stages of Diabetic Retinopathy.
Neuroophthalmology. 2019 Nov 25;44(4):226-235. doi: 10.1080/01658107.2019.1671465. eCollection 2020.
2
The effectiveness of automatic pupillometry as a screening method to detect diabetic autonomic neuropathy.
Int Ophthalmol. 2020 Nov;40(11):3127-3134. doi: 10.1007/s10792-020-01499-x. Epub 2020 Jul 4.
3
Static and dynamic pupillary features in graves' ophthalmopathy.
Clin Exp Optom. 2023 Jul;106(5):551-555. doi: 10.1080/08164622.2022.2059344. Epub 2022 Apr 1.
4
Use of automated quantitative pupillometric evaluation for monitoring the severity of diabetic retinopathy.
Arq Bras Oftalmol. 2021 Jan-Feb;84(1):37-44. doi: 10.5935/0004-2749.20210007.
5
Autonomic dysfunction detection by an automatic pupillometer as a non-invasive test in patients recovered from COVID-19.
Graefes Arch Clin Exp Ophthalmol. 2021 Sep;259(9):2821-2826. doi: 10.1007/s00417-021-05209-w. Epub 2021 Apr 27.
6
Static and dynamic pupillometry data of healthy individuals.
Clin Exp Optom. 2018 Sep;101(5):659-665. doi: 10.1111/cxo.12659. Epub 2018 Jan 21.
7
Static and Dynamic Pupillary Characteristics in Clinically Unilateral Pseudoexfoliation Syndrome.
J Glaucoma. 2018 Jun;27(6):552-557. doi: 10.1097/IJG.0000000000000953.
8
Static and Dynamic Pupil Characteristics in Myopic Anisometropic Amblyopia.
Beyoglu Eye J. 2020 Jul 29;5(2):86-92. doi: 10.14744/bej.2020.08760. eCollection 2020.
9
Static and dynamic pupil characteristics in pseudoexfoliation syndrome and glaucoma.
Clin Exp Optom. 2020 May;103(3):332-338. doi: 10.1111/cxo.12945. Epub 2019 Jul 30.

引用本文的文献

3
Basics, benefits, and pitfalls of pupillometers assessing visual function.
Eye (Lond). 2024 Aug;38(12):2415-2421. doi: 10.1038/s41433-024-03151-9. Epub 2024 May 27.
4
Dynamic and Static Pupil Changes After Near Work: Comparison Between Reading a Book and Using a Smartphone.
Beyoglu Eye J. 2022 Nov 15;7(4):253-260. doi: 10.14744/bej.2022.64325. eCollection 2022.
5
Retinal neural dysfunction in diabetes revealed with handheld chromatic pupillometry.
Clin Exp Ophthalmol. 2022 Sep;50(7):745-756. doi: 10.1111/ceo.14116. Epub 2022 Jun 13.
6
Dynamic Pupillometry in Type 2 Diabetes: Pupillary Autonomic Dysfunction and the Severity of Diabetic Retinopathy.
Clin Ophthalmol. 2020 Nov 17;14:3923-3930. doi: 10.2147/OPTH.S279872. eCollection 2020.

本文引用的文献

1
Melanopsin-mediated pupil function is impaired in Parkinson's disease.
Sci Rep. 2018 May 17;8(1):7796. doi: 10.1038/s41598-018-26078-0.
2
Pupillary Abnormalities with Varying Severity of Diabetic Retinopathy.
Sci Rep. 2018 Apr 4;8(1):5636. doi: 10.1038/s41598-018-24015-9.
3
Static and dynamic pupillometry data of healthy individuals.
Clin Exp Optom. 2018 Sep;101(5):659-665. doi: 10.1111/cxo.12659. Epub 2018 Jan 21.
4
Pupillary responses in non-proliferative diabetic retinopathy.
Sci Rep. 2017 Mar 23;7:44987. doi: 10.1038/srep44987.
5
The Effects of Short-Term Light Adaptation on the Human Post-Illumination Pupil Response.
Invest Ophthalmol Vis Sci. 2016 Oct 1;57(13):5672-5680. doi: 10.1167/iovs.16-19934.
6
Changes in pupil size following panretinal retinal photocoagulation: conventional laser vs pattern scan laser (PASCAL).
Eye (Lond). 2016 Oct;30(10):1359-1364. doi: 10.1038/eye.2016.135. Epub 2016 Jul 8.
7
The Pupillary Light Reflex in Idiopathic Intracranial Hypertension.
Invest Ophthalmol Vis Sci. 2016 Jan 1;57(1):23-9. doi: 10.1167/iovs.15-18181.
8
Changes in Pupil Size Following Panretinal and Focal/Grid Retinal Photocoagulation: Automatic Infrared Pupillometry Study.
J Ocul Pharmacol Ther. 2016 Apr;32(3):172-7. doi: 10.1089/jop.2015.0080. Epub 2015 Nov 18.
9
Type 2 diabetes and cardiac autonomic neuropathy screening using dynamic pupillometry.
Diabet Med. 2015 Nov;32(11):1470-8. doi: 10.1111/dme.12752. Epub 2015 Apr 7.
10
Disproportionate pupillary involvement in diabetic autonomic neuropathy.
Clin Auton Res. 2014 Dec;24(6):305-9. doi: 10.1007/s10286-014-0258-6. Epub 2014 Nov 7.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验