Suppr超能文献

呼气末正压对犬血管外肺水及中心血容量的影响。

Effects of PEEP on extravascular lung water and central blood volume in the dog.

作者信息

Frostell C, Blomqvist H, Wickerts C J

机构信息

Department of Anaesthesia, Danderyd Hospital, Sweden.

出版信息

Acta Anaesthesiol Scand. 1987 Nov;31(8):711-6. doi: 10.1111/j.1399-6576.1987.tb02650.x.

Abstract

Twenty-four mongrel dogs were anaesthetized and ventilated mechanically in the supine position. Extravascular lung water (EVLW) and central blood volume (CBV) were measured with a double indicator (dye/cold) dilution technique. Both indicators were detected intravascularly in the aortic root with a fibreoptic thermistor catheter. Seven dogs ventilated with a positive end-expiratory pressure (PEEP) of 1.0 kPa (10 cmH2O) for a short period of time (less than 20 min) displayed no significant change in EVLW as measured with the indicator dilution technique (= EVLWi), while reductions were seen in both CBV (15%, P less than 0.01) and cardiac output (CO-thermodilution technique) (10%, P less than 0.05). Another seven dogs ventilated with a PEEP of 1.0 kPa for 8 h showed a gradual increase in EVLWi. After 8 h, a mean increase of 34% (P less than 0.01) was recorded, and the increase was also verified by post-mortem gravimetric determination of EVLW (= EVLWg), displaying an increase of 61% (P less than 0.01). In five dogs ventilated with zero end-expiratory pressure (ZEEP) for 8 h, no changes in EVLWi, CO, and CBV were observed, and EVLWg was mean 4.39 g/kg body weight (BW). Five additional dogs were sacrificed after 15 min of anaesthesia without catheterization and EVLWg was found to be 4.24 g/kg BW. It is concluded that EVLWi does not change measurably during ZEEP or short periods of PEEP. However, long periods (8 h) of PEEP result in elevated EVLWi values. Gravimetry supports these conclusions.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

24只杂种犬被麻醉后仰卧位进行机械通气。采用双指示剂(染料/冷)稀释技术测量血管外肺水(EVLW)和中心血容量(CBV)。两种指示剂均通过光纤热敏电阻导管在主动脉根部血管内进行检测。7只犬短时间(少于20分钟)以1.0 kPa(10 cmH₂O)的呼气末正压(PEEP)通气,指示剂稀释技术测量的EVLW(= EVLWi)无显著变化,而CBV降低了15%(P<0.01),心输出量(热稀释技术测量)降低了10%(P<0.05)。另外7只犬以1.0 kPa的PEEP通气8小时,EVLWi逐渐升高。8小时后,平均升高34%(P<0.01),死后重量法测定的EVLW(= EVLWg)也证实了这一升高,升高了61%(P<0.01)。5只犬以零呼气末正压(ZEEP)通气8小时,EVLWi、心输出量和CBV均无变化,EVLWg平均为4.39 g/kg体重(BW)。另外5只犬麻醉15分钟后未插管处死,发现EVLWg为4.24 g/kg BW。结论是,在ZEEP或短时间PEEP期间,EVLWi无明显变化。然而,长时间(8小时)的PEEP会导致EVLWi值升高。重量法支持这些结论。(摘要截断于250字)

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验