提高浸润性乳腺癌分子亚型的鉴别能力:来自乳腺 MRI 的多个定量参数的比较。

Improved discrimination of molecular subtypes in invasive breast cancer: Comparison of multiple quantitative parameters from breast MRI.

机构信息

Department of Radiology, the First Affiliated Hospital of China Medical University, Shenyang 110001, China.

Department of Radiology, the First Affiliated Hospital of China Medical University, Shenyang 110001, China.

出版信息

Magn Reson Imaging. 2021 Apr;77:148-158. doi: 10.1016/j.mri.2020.12.001. Epub 2020 Dec 9.

Abstract

PURPOSE

To compare multiple quantitative parameters from breast magnetic resonance imaging (MRI) with the synthetic MRI sequence included for discrimination of molecular subtypes of invasive breast cancer.

MATERIALS AND METHODS

Between March 2019 and September 2020, two hundred breast cancer patients underwent preoperative breast multiparametric MRI examinations including synthetic MRI, diffusion weighted imaging (DWI) and dynamic contrast enhancement (DCE)-MRI sequences. MRI morphological features, T1 and T2 relaxation times (T1, T2) and proton density (PD) values from synthetic MRI, K, K, and V from DCE-MRI, mean apparent diffusion coefficient (ADC) from DWI and tumor volume were measured. Quantitative parameters were compared according to molecular markers and subtypes. Logistic regression were performed to find the related MRI parameters and establish combined parameters. The comparison between single and combined quantitative parameters by using DeLong tests.

RESULTS

T1, T2 values were significantly higher in hormone receptor (HR)- negative and Ki67 > 14% tumors (p < 0.05). Human epidermal growth factor receptor 2 (HER2)-positive tumors demonstrated significantly higher K and K (p < 0.01). Mean ADC values were significantly decreased in HR-positive and Ki67 > 14% tumors (p < 0.01). Tumor volumes were significantly higher in HER2-positive and Ki67 > 14% tumors (p < 0.05). Independent influencing factors were lower T2 values (p < 0.001), smaller tumor volume (p = 0.031) and higher mean ADC (p = 0.002) associated with luminal A subtype, while T1 values (p = 0.007) was the only quantitative parameter associated with triple-negative subtype. The diagnostic efficiency of combined parameters (T2 + mean ADC + volume) (AUC = 0.765) was significantly higher than that of mean ADC (AUC = 0.666, p = 0.031 by DeLong test) and volume (AUC = 0.650, p = 0.008 by DeLong test) for separating luminal A subtype.

CONCLUSIONS

MRI quantitative parameters could help distinguish molecular markers and subtypes. The emerging synthetic MRI parameters - T1 values were associated with the TN subtype, and combined parameters with added T2 values might improve the discrimination of the luminal A subtype. Application of synthetic MRI can enrich quantitative descriptors from breast MRI.

摘要

目的

比较乳腺磁共振成像(MRI)的多个定量参数与合成 MRI 序列,以区分浸润性乳腺癌的分子亚型。

材料与方法

在 2019 年 3 月至 2020 年 9 月期间,200 例乳腺癌患者接受了术前乳腺多参数 MRI 检查,包括合成 MRI、弥散加权成像(DWI)和动态对比增强(DCE)-MRI 序列。测量 MRI 形态学特征、合成 MRI 的 T1 和 T2 弛豫时间(T1、T2)和质子密度(PD)值、DCE-MRI 的 K、K 和 V、DWI 的平均表观扩散系数(ADC)和肿瘤体积。根据分子标志物和亚型比较定量参数。使用逻辑回归寻找相关的 MRI 参数并建立联合参数。通过 DeLong 检验比较单变量和联合定量参数的性能。

结果

激素受体(HR)阴性和 Ki67>14%肿瘤的 T1、T2 值明显升高(p<0.05)。人表皮生长因子受体 2(HER2)阳性肿瘤的 K 和 K 值明显升高(p<0.01)。HR 阳性和 Ki67>14%肿瘤的平均 ADC 值明显降低(p<0.01)。HER2 阳性和 Ki67>14%肿瘤的肿瘤体积明显增大(p<0.05)。独立影响因素为 T2 值较低(p<0.001)、肿瘤体积较小(p=0.031)和平均 ADC 值较高(p=0.002)与管腔 A 型有关,而 T1 值(p=0.007)是唯一与三阴性型相关的定量参数。联合参数(T2+平均 ADC+体积)(AUC=0.765)的诊断效率明显高于平均 ADC(AUC=0.666,p=0.031,DeLong 检验)和体积(AUC=0.650,p=0.008,DeLong 检验)用于区分管腔 A 型。

结论

MRI 定量参数有助于区分分子标志物和亚型。新兴的合成 MRI 参数-T1 值与 TN 亚型相关,增加 T2 值的联合参数可能有助于提高管腔 A 型的鉴别能力。合成 MRI 的应用可以丰富乳腺 MRI 的定量描述符。