Suppr超能文献

当用于估计深蹲和卧推向心速度时,OUTPUT 运动单元是否可靠和有效?

Is the OUTPUT Sports Unit Reliable and Valid When Estimating Back Squat and Bench Press Concentric Velocity?

机构信息

School of Kinesiology, George Mason University, Manassas, Virginia.

出版信息

J Strength Cond Res. 2022 Aug 1;36(8):2069-2076. doi: 10.1519/JSC.0000000000003782. Epub 2020 Dec 16.

Abstract

Merrigan, JJ and Martin, JR. Is the OUTPUT sports unit reliable and valid when estimating back squat and bench press concentric velocity? J Strength Cond Res 36(8): 2069-2076, 2022-This study evaluated the reliability and concurrent validity of the OUTPUT sports inertial unit to measure concentric velocity of free-weight back squat and bench press exercises. Eleven men and women performed back squat and bench press 1 repetition maximum (1RM) testing. One week later, subjects performed 3 repetitions of each exercise with 35, 45, 55, 65, 75, and 85% 1RM (18 total repetitions). The OUTPUT and 4 cable extension transducers (criterion) simultaneously recorded the mean and peak velocity. The OUTPUT had acceptable reliability for all loads except 85% 1RM for back squat and bench press (intraclass correlation coefficient = 0.72-0.96, coefficient of variation = 0.03-0.12). High systematic biases existed for the mean and peak velocity for the back squat and bench press, according to Bland-Altman plot's wide limits of agreement and ordinary least products regressions. According to Bland-Altman plots, OUTPUT tended to overestimate bench press velocity and overestimate back squat velocity at slower velocities. Least products regression analyses determined proportional bias existed for the mean and peak velocity of the back squat and peak velocity of the bench press. In conclusion, researchers and practitioners are advised not to compare velocity estimates of the OUTPUT unit with criterion devices because these methods cannot be used interchangeably. However, because of the demonstrated reliability when estimating the mean and peak velocity, strength and conditioning practitioners may find the OUTPUT unit valuable for monitoring performance of the back squat and bench press exercises. Yet, caution should be taken when evaluating loads ≥85% 1RM.

摘要

梅里根,JJ 和马丁,JR. OUTPUT 运动惯性单元在估计深蹲和卧推向心速度时是否可靠和有效?J 力量与调节研究 36(8):2069-2076,2022-本研究评估了 OUTPUT 运动惯性单元测量自由重量深蹲和卧推练习向心速度的可靠性和同时效度。11 名男性和女性进行了深蹲和卧推 1 次最大重复次数(1RM)测试。一周后,受试者以 35%、45%、55%、65%、75%和 85%1RM(共 18 次重复)进行了每个练习的 3 次重复。OUTPUT 和 4 个电缆延伸换能器(标准)同时记录平均速度和峰值速度。除了深蹲的 85%1RM 和卧推的 OUTPUT 外,所有负荷的可靠性均可接受(组内相关系数=0.72-0.96,变异系数=0.03-0.12)。根据 Bland-Altman 图的宽一致性界限和普通最小二乘回归,深蹲和卧推的平均速度和峰值速度存在较大的系统偏差。根据 Bland-Altman 图,OUTPUT 倾向于高估卧推速度,并在较慢速度下高估深蹲速度。最小二乘回归分析确定了深蹲的平均速度和峰值速度以及卧推的峰值速度存在比例偏差。总之,研究人员和从业者应避免将 OUTPUT 单元的速度估计与标准设备进行比较,因为这两种方法不能互换使用。然而,由于在估计平均速度和峰值速度方面表现出的可靠性,力量和调节从业者可能会发现 OUTPUT 单元在监测深蹲和卧推练习的性能方面很有价值。然而,在评估负载≥85%1RM 时应谨慎。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验