Suppr超能文献

腕戴式活动设备评估青少年身体活动的有效性:比较研究。

Validity of Wrist-Wearable Activity Devices for Estimating Physical Activity in Adolescents: Comparative Study.

机构信息

School of Kinesiology, Shanghai University of Sport, Shanghai, China.

出版信息

JMIR Mhealth Uhealth. 2021 Jan 7;9(1):e18320. doi: 10.2196/18320.

Abstract

BACKGROUND

The rapid advancements in science and technology of wrist-wearable activity devices offer considerable potential for clinical applications. Self-monitoring of physical activity (PA) with activity devices is helpful to improve the PA levels of adolescents. However, knowing the accuracy of activity devices in adolescents is necessary to identify current levels of PA and assess the effectiveness of intervention programs designed to increase PA.

OBJECTIVE

The study aimed to determine the validity of the 11 commercially available wrist-wearable activity devices for monitoring total steps and total 24-hour total energy expenditure (TEE) in healthy adolescents under simulated free-living conditions.

METHODS

Nineteen (10 male and 9 female) participants aged 14 to 18 years performed a 24-hour activity cycle in a metabolic chamber. Each participant simultaneously wore 11 commercial wrist-wearable activity devices (Mi Band 2 [XiaoMi], B2 [Huawei], Bong 2s [Meizu], Amazfit [Huamei], Flex [Fitbit], UP3 [Jawbone], Shine 2 [Misfit], GOLiFE Care-X [GoYourLife], Pulse O2 [Withings], Vivofit [Garmin], and Loop [Polar Electro]) and one research-based triaxial accelerometer (GT3X+ [ActiGraph]). Criterion measures were total EE from the metabolic chamber (mcTEE) and total steps from the GT3X+ (AGsteps).

RESULTS

Pearson correlation coefficients r for 24-hour TEE ranged from .78 (Shine 2, Amazfit) to .96 (Loop) and for steps ranged from 0.20 (GOLiFE) to 0.57 (Vivofit). Mean absolute percent error (MAPE) for TEE ranged from 5.7% (Mi Band 2) to 26.4% (Amazfit) and for steps ranged from 14.2% (Bong 2s) to 27.6% (Loop). TEE estimates from the Mi Band 2, UP3, Vivofit, and Bong 2s were equivalent to mcTEE. Total steps from the Bong 2s were equivalent to AGsteps.

CONCLUSIONS

Overall, the Bong 2s had the best accuracy for estimating TEE and total steps under simulated free-living conditions. Further research is needed to examine the validity of these devices in different types of physical activities under real-world conditions.

摘要

背景

可穿戴式腕部活动设备在科学技术方面的快速发展为临床应用提供了巨大的潜力。使用活动设备进行身体活动(PA)的自我监测有助于提高青少年的 PA 水平。然而,了解活动设备在青少年中的准确性对于确定当前的 PA 水平以及评估旨在提高 PA 的干预计划的效果是必要的。

目的

本研究旨在确定在模拟自由生活条件下,11 种市售腕戴式活动设备监测健康青少年总步数和总 24 小时总能量消耗(TEE)的有效性。

方法

19 名(10 名男性和 9 名女性)年龄在 14 至 18 岁的参与者在代谢室内进行了 24 小时的活动循环。每位参与者同时佩戴 11 种市售腕戴式活动设备(小米手环 2 [XiaoMi]、B2 [Huawei]、邦 2s [Meizu]、Amazfit [Huamei]、Flex [Fitbit]、UP3 [Jawbone]、Shine 2 [Misfit]、GOLiFE Care-X [GoYourLife]、Pulse O2 [Withings]、Vivofit [Garmin]和 Loop [Polar Electro])和一个基于研究的三轴加速度计(GT3X+ [ActiGraph])。标准测量值为代谢室的总 EE(mcTEE)和 GT3X+的总步数(AGsteps)。

结果

24 小时 TEE 的 Pearson 相关系数 r 范围为 0.78(Shine 2、Amazfit)至 0.96(Loop),步数范围为 0.20(GOLiFE)至 0.57(Vivofit)。TEE 的平均绝对百分比误差(MAPE)范围为 5.7%(Mi Band 2)至 26.4%(Amazfit),步数范围为 14.2%(Bong 2s)至 27.6%(Loop)。Mi Band 2、UP3、Vivofit 和 Bong 2s 的 TEE 估计值与 mcTEE 相当。Bong 2s 的总步数与 AGsteps 相当。

结论

总体而言,Bong 2s 在模拟自由生活条件下估计 TEE 和总步数的准确性最高。需要进一步研究这些设备在现实条件下进行不同类型身体活动时的有效性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0529/7819784/1beb84a2f802/mhealth_v9i1e18320_fig1.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验