A method for measuring the tilt and decentration of intraocular lenses (IOLs) in the static eye using the Purkinje image locations is presented. The patient fixates on a target that is coaxial with the camera or is at a predetermined angle with the camera axis. A telecentric stop is introduced in the camera so the positions of the Purkinje images on the film are independent of their distance from the camera. Measurements of the image locations on the film are used with anterior chamber depth and corneal curvature measurement to calculate the tilt and decentration of the IOL. In a group of 14 randomly selected patients with posterior chamber IOLs, 13 gave Purkinje images that could be measured. The average tilt was 7.8 degrees and the average decentration was 0.7 mm.

摘要

提出了一种利用普尔钦耶图像位置测量静态眼中人工晶状体(IOL)倾斜度和偏心度的方法。患者注视与相机同轴或与相机轴成预定角度的目标。在相机中引入远心光阑,使得胶片上普尔钦耶图像的位置与其到相机的距离无关。胶片上图像位置的测量值与前房深度和角膜曲率测量值一起用于计算IOL的倾斜度和偏心度。在一组随机选择的14例植入后房型IOL的患者中,13例获得了可测量的普尔钦耶图像。平均倾斜度为7.8度,平均偏心度为0.7毫米。