Suppr超能文献

种植体基台螺丝松动:文献综述

Abutment screw loosening in implants: A literature review.

作者信息

Alsubaiy Ebrahim F

机构信息

Assistant Professor, Department of Prosthodontics, King Khalid University, Abha, Saudi Arabia.

出版信息

J Family Med Prim Care. 2020 Nov 30;9(11):5490-5494. doi: 10.4103/jfmpc.jfmpc_1343_20. eCollection 2020 Nov.

Abstract

This review was intended on major factors contributing to abutment screw loosening. A search of Pubmed and Google Scholar, as well as a manual search, was conducted. Publications and articles accepted for publication up to February 2020 were included. Out of 150 studies retrieved, a total of 57 were selected for this review. Dental implants are associated with a complexity of abutment screw loosening. Implantologists and prosthodontists should be aware of factors that contribute to this problem. In this review previously identified factors were collected, the consideration of which can help to reduce the frequency of abutment screw loosening.

摘要

本综述旨在探讨导致基台螺丝松动的主要因素。我们检索了PubMed和谷歌学术,并进行了人工检索。纳入了截至2020年2月已发表或被接受发表的文献和文章。在检索到的150项研究中,共筛选出57项用于本综述。牙种植体与基台螺丝松动的复杂性相关。种植医生和口腔修复医生应了解导致该问题的因素。在本综述中,收集了先前已确定的因素,考虑这些因素有助于降低基台螺丝松动的频率。

相似文献

1
Abutment screw loosening in implants: A literature review.
J Family Med Prim Care. 2020 Nov 30;9(11):5490-5494. doi: 10.4103/jfmpc.jfmpc_1343_20. eCollection 2020 Nov.
2
Mechanism of and factors associated with the loosening of the implant abutment screw: A review.
J Esthet Restor Dent. 2019 Jul;31(4):338-345. doi: 10.1111/jerd.12494. Epub 2019 May 31.
3
Abutment screw loosening in angulation-correcting implants: An in vitro study.
J Prosthet Dent. 2019 Jan;121(1):151-155. doi: 10.1016/j.prosdent.2018.03.005. Epub 2018 Jul 10.
6
Measuring abutment/implant joint integrity with the Periotest instrument.
Int J Oral Maxillofac Implants. 1999 Sep-Oct;14(5):681-8.
7
Effect of double conical abutment screw on implant preload.
Clin Oral Implants Res. 2016 May;27(5):553-7. doi: 10.1111/clr.12623. Epub 2015 Aug 6.
9
Effect of implant abutment connection designs, and implant diameters on screw loosening before and after cyclic loading: In-vitro study.
Dent Mater. 2019 Nov;35(11):e265-e271. doi: 10.1016/j.dental.2019.07.026. Epub 2019 Aug 16.
10
Effect of Double Screw on Abutment Screw Loosening in Single-Implant Prostheses.
Int J Prosthodont. 2016 Sep-Oct;29(5):445-7. doi: 10.11607/ijp.4791.

引用本文的文献

3
Factors Influencing the Screw Stability of Implant-Supported Single Crowns: An In Vitro Study.
Materials (Basel). 2025 Jan 23;18(3):506. doi: 10.3390/ma18030506.
5
Influence of Trabecular Bone Presence on Osseodensification Instrumentation: An In Vivo Study in Sheep.
Biomimetics (Basel). 2024 Sep 19;9(9):568. doi: 10.3390/biomimetics9090568.
6
Dental Implant Abutment Screw Loss: Presentation of 10 Cases.
J Funct Biomater. 2024 Apr 9;15(4):96. doi: 10.3390/jfb15040096.
8
Silver coating on dental implant-abutment connection screws as potential strategy to prevent loosening and minimizing bacteria adhesion.
Front Bioeng Biotechnol. 2024 Jan 9;11:1293582. doi: 10.3389/fbioe.2023.1293582. eCollection 2023.
10
Abutment mechanical complications of a Morse taper connection implant system: A 1- to 9-year retrospective study.
Clin Implant Dent Relat Res. 2022 Oct;24(5):683-695. doi: 10.1111/cid.13115. Epub 2022 Jul 6.

本文引用的文献

2
Clinical study on screw loosening in dental implant prostheses: a 6-year retrospective study.
J Korean Assoc Oral Maxillofac Surg. 2020 Apr 30;46(2):133-142. doi: 10.5125/jkaoms.2020.46.2.133.
4
Factors associated with abutment screw loosening in single implant supported crowns: A cross-sectional study.
Med J Armed Forces India. 2020 Jan;76(1):37-40. doi: 10.1016/j.mjafi.2018.06.011. Epub 2018 Oct 10.
5
Effect of implant abutment connection designs, and implant diameters on screw loosening before and after cyclic loading: In-vitro study.
Dent Mater. 2019 Nov;35(11):e265-e271. doi: 10.1016/j.dental.2019.07.026. Epub 2019 Aug 16.
6
Effect of fluid contamination on the reverse torque values of abutment screws at implant-abutment connections.
J Prosthet Dent. 2020 Apr;123(4):618-621. doi: 10.1016/j.prosdent.2019.05.001. Epub 2019 Jul 26.
7
In vitro assessment of connection strength and stability of internal implant-abutment connections.
Clin Biomech (Bristol). 2019 May;65:92-99. doi: 10.1016/j.clinbiomech.2019.03.007. Epub 2019 Mar 13.
8
Assessment of preload, remaining torque, and removal torque in abutment screws under different frictional conditions: A finite element analysis.
J Prosthet Dent. 2019 Mar;121(3):548.e1-548.e7. doi: 10.1016/j.prosdent.2018.10.035. Epub 2019 Feb 11.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验