文献检索文档翻译深度研究
Suppr Zotero 插件Zotero 插件
邀请有礼套餐&价格历史记录

新学期,新优惠

限时优惠:9月1日-9月22日

30天高级会员仅需29元

1天体验卡首发特惠仅需5.99元

了解详情
不再提醒
插件&应用
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
高级版
套餐订阅购买积分包
AI 工具
文献检索文档翻译深度研究
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2025

Temperature and current flow effects of different electrode placement in shoulder capacitive-resistive electric transfer applications: a cadaveric study.

作者信息

Rodríguez-Sanz Jacobo, López-de-Celis Carlos, Hidalgo-García César, Canet-Vintró Max, Fanlo-Mazas Pablo, Pérez-Bellmunt Albert

机构信息

Universitat Internacional de Catalunya. Actium functional anatomy group. Faculty of Medicine and Health Sciences, Barcelona, Spain.

Fundació Institut Universitari per a la recerca a l'Atenció Primària de Salut Jordi Gol i Gurina, Barcelona, Spain.

出版信息

BMC Musculoskelet Disord. 2021 Feb 4;22(1):139. doi: 10.1186/s12891-020-03918-7.


DOI:10.1186/s12891-020-03918-7
PMID:33541324
原文链接:https://pmc.ncbi.nlm.nih.gov/articles/PMC7860630/
Abstract

BACKGROUND: Impingement syndrome is currently estimated to represent 60% of all shoulder pain disorders. Capacitive-Resistive electric transfer therapy is aimed to provoke temperature and current flow changes in superficial and deep tissues. This in vitro study has evaluated the variation of temperature and current flow in the shoulder tissues during two different areas of application of the movable capacitive-resistive electric transfer electrode. METHODS: A cross-sectional study designed, five fresh cryopreserved cadavers (10 shoulders) were included in this study. Four interventions (capacitive and resistive modes; low- and high-power) were performed for 5 min each by a diathermy "T-Plus" device in two shoulder regions: postero-superior and antero-lateral. Supraspinatus tendon, glenohumeral capsule and superficial temperatures were recorded at 1-min intervals and 5 min after treatment. RESULTS: A statistically significant difference was found only for the superficial area and time interaction, with high power-resistive application at the postero-superior shoulder area (P< 0.035). All the applications showed a 5 min after treatment temperature increase compared with the basal data, in all the application points. Superficial temperature in the high power-resistive application showed the greatest percent increase (42.93% ± 22.58), followed by the temperature in the tendon area with the same high power-resistive application (22.97% ± 14.70). The high power-resistive application showed the greatest percent of temperature increase in the applications, reaching 65.9% ± 22.96 at 5-min at the superficial level, and 32% ± 24.25 at 4-min at the level of the supraspinatus tendon. At the capsule level, high power-resistive was also the application that showed the greatest percent of increase, with 21.52% ± 16.16. The application with the lowest percent of temperature increase was the low power-capacitive, with a mean value of 4.86% at supraspinatus tendon level and 7.47% at capsular level. CONCLUSION: The shoulder postero-superior or antero-lateral areas of application of capacitive-resistive electric transfer did not cause statistically significant differences in the temperature changes in either supraspinatus tendon or glenohumeral capsule tissues in cadaveric samples. The high power-resistive application in the postero-superior area significantly increased superficial temperature compared with the same application in the antero-lateral position area.

摘要
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/e19e/7860630/e41d36545ce7/12891_2020_3918_Fig1_HTML.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/e19e/7860630/e41d36545ce7/12891_2020_3918_Fig1_HTML.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/e19e/7860630/e41d36545ce7/12891_2020_3918_Fig1_HTML.jpg

相似文献

[1]
Temperature and current flow effects of different electrode placement in shoulder capacitive-resistive electric transfer applications: a cadaveric study.

BMC Musculoskelet Disord. 2021-2-4

[2]
Thermal and non-thermal effects off capacitive-resistive electric transfer application on the Achilles tendon and musculotendinous junction of the gastrocnemius muscle: a cadaveric study.

BMC Musculoskelet Disord. 2020-1-20

[3]
Thermal and Current Flow Effects of a Capacitive-Resistive Electric Transfer Application Protocol on Chronic Elbow Tendinopathy. A Cadaveric Study.

Int J Environ Res Public Health. 2021-1-24

[4]
Thermal and non-thermal effects of capacitive-resistive electric transfer application on different structures of the knee: a cadaveric study.

Sci Rep. 2020-12-18

[5]
Is Tecar Therapy Effective on Biceps Femoris and Quadriceps Rehabilitation? A Cadaveric Study.

J Sport Rehabil. 2022-8-1

[6]
Biomechanical Role of Capsular Continuity in Superior Capsule Reconstruction for Irreparable Tears of the Supraspinatus Tendon.

Am J Sports Med. 2016-6

[7]
Biomechanical Effects of Acromioplasty on Superior Capsule Reconstruction for Irreparable Supraspinatus Tendon Tears.

Am J Sports Med. 2016-1

[8]
Biomechanical Effect of Thickness and Tension of Fascia Lata Graft on Glenohumeral Stability for Superior Capsule Reconstruction in Irreparable Supraspinatus Tears.

Arthroscopy. 2016-3

[9]
Superior Capsule Reconstruction With a 3 mm-Thick Dermal Allograft Partially Restores Glenohumeral Stability in Massive Posterosuperior Rotator Cuff Deficiency: A Dynamic Robotic Shoulder Model.

Am J Sports Med. 2021-7

[10]
Effect of Anterior Capsular Laxity on Horizontal Abduction and Forceful Internal Impingement in a Cadaveric Model of the Throwing Shoulder.

Am J Sports Med. 2015-7

引用本文的文献

[1]
Evaluation of the efficacy of transfer energy capacitive and resistive therapy in patients with knee osteoarthritis.

Turk J Med Sci. 2024-10-7

[2]
Comparison Between the Effects of Transfer Energy Capacitive and Resistive Therapy and Therapeutic Ultrasound on Hamstring Muscle Shortness in Male Athletes: A Single-Blind Randomized Controlled Trial.

Galen Med J. 2023-8-19

[3]
Effects of Transfer Energy Capacitive and Resistive On Musculoskeletal Pain: A Systematic Review and Meta-Analysis:

Galen Med J. 2022-11-17

[4]
TECAR Therapy Associated with High-Intensity Laser Therapy (Hilt) and Manual Therapy in the Treatment of Muscle Disorders: A Literature Review on the Theorised Effects Supporting Their Use.

J Clin Med. 2022-10-19

[5]
The Thermal Influence of an Electromagnetic Field with a Radio Frequency Depending on the Type of Electrode Used.

Int J Environ Res Public Health. 2022-9-9

[6]
Comparison of resistive capacitive energy transfer therapy on cadaveric molars and incisors with and without implants.

Sci Rep. 2022-7-13

本文引用的文献

[1]
Thermal and non-thermal effects off capacitive-resistive electric transfer application on the Achilles tendon and musculotendinous junction of the gastrocnemius muscle: a cadaveric study.

BMC Musculoskelet Disord. 2020-1-20

[2]
Does the Application of Tecar Therapy Affect Temperature and Perfusion of Skin and Muscle Microcirculation? A Pilot Feasibility Study on Healthy Subjects.

J Altern Complement Med. 2019-10-3

[3]
Subacromial impingement syndrome: management challenges.

Orthop Res Rev. 2018-10-23

[4]
Effects of a capacitive-resistive electric transfer therapy on physiological and biomechanical parameters in recreational runners: A randomized controlled crossover trial.

Phys Ther Sport. 2018-5-26

[5]
Effect of Capacitive and Resistive electric transfer on changes in muscle flexibility and lumbopelvic alignment after fatiguing exercise.

J Phys Ther Sci. 2018-5

[6]
Comparison of Muscle Temperature Increases Produced by Moist Hot Pack and ThermoStim Probe.

J Sport Rehabil. 2018-12-17

[7]
Rotator cuff calcific tendinopathy: from diagnosis to treatment.

Acta Biomed. 2018-1-19

[8]
Impingement Syndrome of the Shoulder.

Dtsch Arztebl Int. 2017-11-10

[9]
Sports and environmental temperature: From warming-up to heating-up.

Temperature (Austin). 2017-8-4

[10]
Tendon injury and repair - A perspective on the basic mechanisms of tendon disease and future clinical therapy.

Acta Biomater. 2017-9-1

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

推荐工具

医学文档翻译智能文献检索