Department of Orthodontics, Faculty of Health, University of Witten/Herdecke, Witten, Germany.
Faculty of Health, Institute for Medical Biometry and Epidemiology, University of Witten/Herdecke, Witten, Germany.
PLoS One. 2021 Feb 26;16(2):e0247716. doi: 10.1371/journal.pone.0247716. eCollection 2021.
Development of white spot lesions (WSLs) during orthodontic treatment is a common risk factor. Fixation of the orthodontic appliances with glass ionomer cements could reduce the prevalence of WSL's due to their fluoride release capacities. The purpose of this study was to evaluate differences of fluoride release properties from resin-modified and conventional glass ionomer cements (GICs).
The resin-modified GICs Fuji ORTHO LC (GC Orthodontics), Meron Plus QM (VOCO), as well as the conventional GICs Fuji ORTHO (GC Orthodontics), Meron (VOCO) and Ketac Cem Easymix (3M ESPE) were tested in this study. The different types of GICs were applied to hydroxyapatite discs according to the manufacturer's instructions and stored in a solution of TISAB III (Total Ionic Strength Adjustment Buffer III) and fluoride-free water at 37°C. Fluoride measurements were made after 5 minutes, 2 hours, 24 hours, 14 days, 28 days, 2 months, 3 months and 6 months. One factor analysis of variance (ANOVA) was used for the overall comparison of the cumulative fluoride release (from measurement times of 5 minutes to 6 months) between the different materials with the overall level of significance set to 0.05. Tukey's post hoc test was used for post hoc pairwise comparisons in the cumulative fluoride release between the different materials.
The cumulative fluoride release (mean ± sd) in descending order was: Fuji ORTHO LC (221.7 ± 10.29 ppm), Fuji ORTHO (191.5 ± 15.03 ppm), Meron Plus QM (173.0 ± 5.89 ppm), Meron (161.3 ± 7.84 ppm) and Ketac Cem Easymix (154.6 ± 6.09 ppm) within 6 months. Analysis of variance detected a significant difference in the cumulative fluoride release between at least two of the materials (rounded p-value < 0.001). Pairwise analysis with Tukey's post hoc test showed a significant difference in the cumulative fluoride release for all the comparisons except M and MPQM (p = 0.061) and KCE and M (p = 0.517).
Fluoride ions were released cumulatively over the entire test period for all products. When comparing the two products from the same company (Fuji ORTHO LC vs. Fuji ORTHO from GC Orthodontics Europe GmbH and Meron Plus QM vs. Meron from VOCO GmbH, Mannheim, Germany), it can be said that the resin-modified GICs have a higher release than conventional GICs. The highest individual fluoride release of all GICs was at 24 hours. A general statement, whether resin-modified or conventional GICs have a higher release of fluoride cannot be made.
正畸治疗过程中出现白垩斑(WSL)是一种常见的风险因素。用玻璃离子水门汀固定正畸矫治器可以减少 WSL 的发生率,因为它们具有释放氟化物的能力。本研究的目的是评估树脂改良型玻璃离子水门汀(GIC)和传统 GIC 之间氟释放性能的差异。
本研究测试了树脂改良型 GIC 富士 ORTHO LC(GC Orthodontics)、Meron Plus QM(VOCO)以及传统 GIC 富士 ORTHO(GC Orthodontics)、Meron(VOCO)和 Ketac Cem Easymix(3M ESPE)。根据制造商的说明,将不同类型的 GIC 应用于羟基磷灰石盘,并将其储存在 TISAB III(总离子强度调节缓冲液 III)和无氟水中,在 37°C 下储存。在 5 分钟、2 小时、24 小时、14 天、28 天、2 个月、3 个月和 6 个月后测量氟化物。采用单因素方差分析(ANOVA)对不同材料之间累积氟释放(从 5 分钟到 6 个月的测量时间)进行总体比较,总体显著性水平设定为 0.05。采用 Tukey 事后检验对不同材料之间的累积氟释放进行事后两两比较。
在 6 个月内,累积氟释放(均值±标准差)按降序排列为:富士 ORTHO LC(221.7±10.29 ppm)、富士 ORTHO(191.5±15.03 ppm)、Meron Plus QM(173.0±5.89 ppm)、Meron(161.3±7.84 ppm)和 Ketac Cem Easymix(154.6±6.09 ppm)。方差分析检测到至少两种材料之间的累积氟释放存在显著差异(舍入后的 p 值<0.001)。Tukey 事后检验的成对分析显示,除了 M 和 MPQM(p=0.061)和 KCE 和 M(p=0.517)之外,所有比较的累积氟释放均存在显著差异。
所有产品在整个测试期间均累积释放氟离子。当比较同一公司的两种产品(GC Orthodontics Europe GmbH 的富士 ORTHO LC 与富士 ORTHO 和 VOCO GmbH 的 Meron Plus QM 与 Meron)时,可以说树脂改良型 GIC 的释放量高于传统 GIC。所有 GIC 中氟化物的最大单次释放量为 24 小时。一般来说,不能说树脂改良型或传统 GIC 的氟释放量更高。