Tanveer Fahad, Arslan Syed Asadullah, Darain Haider, Ahmad Ashfaq
Dr. Fahad Tanveer, PhD (Scholar) University Institute of Physical Therapy, The University of Lahore, Lahore, Pakistan.
Dr. Syed Asadullah Arslan, PhD University Institute of Physical Therapy, The University of Lahore, Lahore, Pakistan.
Pak J Med Sci. 2021 Mar-Apr;37(2):461-465. doi: 10.12669/pjms.37.2.3621.
To determine intra-rater and inter-rater reliability of hand-held dynamometer for assessing isometric lumbar muscle strength in asymptomatic healthy population.
It was a cross-sectional study conducted at the department of physiotherapy, University of Lahore Teaching Hospital, Lahore, Pakistan, from July 2020 to August 2020 through non probability-purposive sampling technique. Thirty healthy subjects were tested at thirty-degree lumbar flexion and zero-degree lumbar extension positions. Two raters assessed isometric strength of lumbar flexor and extensor muscles, by a hand-held dynamometer. Strength was measured and recorded by each of the two raters and re-assessed after a week. Correlation and pairwise comparison were done between readings. ICC values were calculated for the assessment of isometric lumbar muscle strength using handheld dynamometer.
A total of 30 healthy subjects had participated with mean age of 22.84±1.21 years, height 174.33±6.83 cm, weight 68.58±5.08 kg and BMI 22.52±0.35. Findings showed an excellent intra-rater (ICC 2, k = 0.95 to 0.97) and inter-rater (ICC 2, k = 0.94 to 0.95) reliability.
Hand held dynamometer demonstrated an excellent intra- and inter-rater reliability for assessment of isometric lumbar muscles strength of healthy subject at clinical setting as it is simple to use, portable and cost-effective for the precise measurement of lumbar muscles strength.
确定手持测力计在评估无症状健康人群等长腰背部肌肉力量时的评分者内和评分者间信度。
这是一项横断面研究,于2020年7月至2020年8月在巴基斯坦拉合尔拉合尔大学教学医院物理治疗科通过非概率目的抽样技术进行。30名健康受试者在腰椎前屈30度和腰椎后伸0度位置接受测试。两名评分者使用手持测力计评估腰屈肌和伸肌的等长力量。两名评分者分别测量并记录力量,并在一周后重新评估。对读数进行相关性和成对比较。计算使用手持测力计评估等长腰背部肌肉力量的组内相关系数(ICC)值。
共有30名健康受试者参与,平均年龄22.84±1.21岁,身高174.33±6.83厘米,体重68.58±5.08千克,体重指数22.52±0.35。结果显示评分者内(ICC 2,k = 0.95至0.97)和评分者间(ICC 2,k = 0.94至0.95)信度极佳。
手持测力计在临床环境中评估健康受试者等长腰背部肌肉力量时显示出极佳的评分者内和评分者间信度,因为它使用简单、便于携带且成本效益高,可精确测量腰背部肌肉力量。