Suppr超能文献

使用固定手持式测力计测量髋部肌肉力量和力量发展速率:临床设置的测试者日内可靠性

MEASURES OF HIP MUSCLE STRENGTH AND RATE OF FORCE DEVELOPMENT USING A FIXATED HANDHELD DYNAMOMETER: INTRA-TESTER INTRA-DAY RELIABILITY OF A CLINICAL SET-UP.

作者信息

Ishøi Lasse, Hölmich Per, Thorborg Kristian

机构信息

Sports Orthopaedic Research Center - Copenhagen (SORC-C), Department of Orthopaedic Surgery, Copenhagen University Hospital, Amager-Hvidovre, Denmark.

出版信息

Int J Sports Phys Ther. 2019 Sep;14(5):715-723.

Abstract

BACKGROUND

Evaluation of hip muscle function is considered an important part of the examination and treatment of physically active subjects with hip and groin pain. However, methods to reliably measure explosive hip muscle strength are lacking.

HYPOTHESIS/PURPOSE: The purpose was to investigate the reliability of a clinically available set-up using a fixated handheld dynamometer to test isometric peak force and rate of force development of the hip abductors, adductors, flexors, and extensors.

METHODS

Seventeen subjects (males: 9, females: 8, mean aged 25.4 (+/- 4.2) y, with mean body mass of 73.9 (+/- 15.2) kg, and mean height 174.2 (+/- 12.4) cm) were included. One experienced tester performed all measures in a randomized order. Three trials of isometric peak force and early- (0-100 ms) and late-phase (0-200 ms) rate of force development for the hip abductors, adductors, flexors, and extensors were obtained using a fixated handheld dynamometer. The trial with the highest value for each measure was used for analysis. Test-retest sessions were separated by 30 minutes of rest.

RESULTS

No systematic between-session bias were observed for any of the measures. The relative intra-tester reliability (ICC) for peak force, 0-100 ms rate of force development, and 0-200 ms rate of force development ranged from 0.93-0.96, 0.82-0.93, and 0.85-0.92, respectively, corresponding to good reliability for all force measures.

CONCLUSION

The present study shows that assessment of isometric hip muscle peak force, including early- (0-100 ms) and late-phase (0-200 ms) rate of force development using a fixated handheld dynamometer have good intra-tester reliability for testing of the hip adductors, abductors, flexors and extensors. Thus, in clinical research settings where an isokinetic dynamometer may not always be readily accessible, the present test procedure can be used as a feasible alternative to reliably provide objective of hip muscle function relevant for rehabilitation of patients with hip and groin pain.

LEVEL OF EVIDENCE

Level 3, Reliability study.

摘要

背景

髋部肌肉功能评估被认为是对有髋部和腹股沟疼痛的体育活动人群进行检查和治疗的重要组成部分。然而,目前缺乏可靠测量髋部肌肉爆发力的方法。

假设/目的:目的是研究一种临床可用的固定手持式测力计设置,用于测试髋外展肌、内收肌、屈肌和伸肌的等长峰值力和力发展速率的可靠性。

方法

纳入17名受试者(男性9名,女性8名,平均年龄25.4(±4.2)岁,平均体重73.9(±15.2)kg,平均身高174.2(±12.4)cm)。由一名经验丰富的测试者以随机顺序进行所有测量。使用固定手持式测力计获得髋外展肌、内收肌、屈肌和伸肌的等长峰值力以及早期(0 - 100毫秒)和晚期(0 - 200毫秒)力发展速率的三次试验结果。每次测量中取最高值的试验用于分析。重测 sessions 间隔30分钟休息时间。

结果

所有测量均未观察到系统性的测量间偏差。峰值力、0 - 100毫秒力发展速率和0 - 200毫秒力发展速率的测试者内相对可靠性(ICC)分别为0.93 - 0.96、0.82 - 0.93和0.85 - 0.92,表明所有力测量均具有良好的可靠性。

结论

本研究表明,使用固定手持式测力计评估髋部肌肉等长峰值力,包括早期(0 - 100毫秒)和晚期(0 - 200毫秒)力发展速率,在测试髋内收肌、外展肌、屈肌和伸肌时具有良好的测试者内可靠性。因此,在临床研究环境中,等速测力计可能并非随时可用,本测试程序可作为一种可行的替代方法,可靠地提供与髋部和腹股沟疼痛患者康复相关的髋部肌肉功能的客观指标。

证据水平

3级,可靠性研究。

相似文献

引用本文的文献

本文引用的文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验