Soomro Rabail Rani, Karimi Hossein, Gillani Syed Amir
Dr. Rabail Rani Soomro, PT, Assistant Professor, Sindh Institute of Physical Medicine and Rehabilitation, Karachi, Pakistan.
Hossein Karimi, PT, PhD. Professor Istanbul Gelisim University, Turkey. Adjunct Professor, University Institute of Physiotherapy, University of Lahore, Lahore, Pakistan.
Pak J Med Sci. 2022 May-Jun;38(5):1238-1242. doi: 10.12669/pjms.38.5.5207.
To determine the inter-rater and intra-rater reliability of the hand-held dynamometer in measuring isometric gluteus medius muscle strength in asymptomatic healthy population.
It was a cross sectional study conducted at the department of physiotherapy, Sindh Institute of Physical Medicine and Rehabilitation from March 2021 to April 2021. Thirty healthy subjects aged 18 to 25 years of both sexes and no previous or current complaints of hip or knee pain were included through non-probability purposive sampling technique. The strength of the unilateral isometric gluteus medius muscle was measured using a hand-held dynamometer by two raters at the same day and a week later. Pearson Correlation coefficient was calculated to see the relationship of muscle strength measured by each rater within and between day's sessions. Intra-class correlation was calculated with 95% confidence interval and Standard error of measurements using reliability analysis.
In the present study there were thirty participants studied by two raters, the mean age of participants was 21.53 (SD=±1.40) years, the mean BMI was 24.05 (SD=±1.12) kg/m2 and 70% participants were female and 30% were males. This study showed the mean muscle measurement of participants within days was 12.92 (SD=±0.94), with intra-class correlation ICC (2,2) 0.94 and SEM 0.12 and mean muscle measurement of patients between days was 12.99 (SD=±0.91), with intra-class correlation ICC (2,2) 0.90 and SEM 0.12..
Hand-held dynamometer has shown excellent inter-rater and intra-rater reliability in measuring isometric strength of Gluteus Medius muscle among healthy population. It is convenient to be used in clinical settings and can be a useful outcome tool to assess strength in interventional studies.
确定手持测力计在测量无症状健康人群等长臀中肌肌力时的评分者间信度和评分者内信度。
这是一项于2021年3月至2021年4月在信德物理医学与康复研究所物理治疗科进行的横断面研究。通过非概率目的抽样技术纳入了30名年龄在18至25岁之间、无既往或当前髋部或膝部疼痛主诉的健康受试者,男女不限。同一天,两名评估者使用手持测力计测量单侧等长臀中肌的肌力,一周后再次测量。计算皮尔逊相关系数,以观察每位评估者在当天不同时段以及不同天之间所测量的肌肉力量之间的关系。使用信度分析计算组内相关系数及95%置信区间和测量标准误差。
在本研究中,两名评估者对30名参与者进行了研究,参与者的平均年龄为21.53(标准差=±1.40)岁,平均体重指数为24.05(标准差=±1.12)kg/m²,70%的参与者为女性,30%为男性。本研究显示,参与者在同一天内的平均肌肉测量值为12.92(标准差=±0.94),组内相关系数ICC(2,2)为0.94,测量标准误差为0.12;不同天之间的平均肌肉测量值为12.99(标准差=±0.91),组内相关系数ICC(2,2)为0.90,测量标准误差为0.12。
手持测力计在测量健康人群等长臀中肌肌力方面显示出优异的评分者间信度和评分者内信度。它便于在临床环境中使用,并且可以作为介入性研究中评估力量的有用结果工具。