Suppr超能文献

二维斑点追踪超声心动图分析运动员左心室旋转运动:一项可行性研究。

Analysis of left ventricular rotational deformation by 2D speckle tracking echocardiography: a feasibility study in athletes.

机构信息

Department of Cardiology, University Hospital Leipzig, Liebigstrasse 20, 04103, Leipzig, Germany.

Division of Arthroscopy, Joint Surgery and Sports Injuries, University Hospital Leipzig, Liebigstrasse 20, 04103, Leipzig, Germany.

出版信息

Int J Cardiovasc Imaging. 2021 Aug;37(8):2369-2386. doi: 10.1007/s10554-021-02213-3. Epub 2021 Mar 18.

Abstract

2D speckle tracking echocardiography (2DSTE) is established to analyse left ventricular (LV) longitudinal function. The analysis of LV rotational deformation is challenging and requires standardization of image acquisition as well as postprocessing analysis. The aim of this study was to test the feasibility to analyse LV rotational deformation using 2DSTE by introducing a novel algorithm for the detection of artefacts. The study was performed in 20 healthy subjects serving as a control group and in 53 competitive sportsmen. Circumferential, radial strain (CS, RS) and LV rotation were analysed by 2DSTE in parasternal short axis views. The stepwise algorithm to exclude potential artefacts starts with the visual estimation of the image quality with respect to complete visualization of all myocardial segments during the entire cardiac cycle followed by the exclusion of data sets in participants with conduction abnormalities. The next step is the optimization of tracking areas and a cross-check of implausible strain waveforms in multiple acquired comparable cineloops. The last step is the exclusion of strain curves with persisting implausible waveforms if standardization failures and incorrect LV wall tracking are fixed. Plausible physiological strain curves were observed in 89% (n = 65/73) of all subjects. In controls all implausible waveforms could be verified as artefacts. The algorithm was applied in 53 professional athletes to test and confirm its feasibility. Abnormal CS waveforms were documented in 25 athletes, verified as artefacts due to tracking failures in 22 athletes and due to incorrect image acquisition in 3 athletes. CS artefacts were mostly located in the basal posterior and lateral LV segments. (endocardial: 6%, n = 4/70; p < 0.05) and basal posterior (endocardial: 8%, n = 5/70; p < 0.05) segments were highly susceptible to artefacts. 2DSTE of parasternal short axis views to analyse circumferential and radial deformation as well as LV rotation is feasible in athletes. The proposed algorithm helps to avoid artefacts and might contribute to standardization of this technique. 2DSTE might provide an interesting diagnostic tool for the detection of viral myocarditis, e.g. in athletes.

摘要

二维斑点追踪超声心动图(2DSTE)常用于分析左心室(LV)的纵向功能。LV 旋转变形的分析具有挑战性,需要对图像采集和后处理分析进行标准化。本研究旨在通过引入一种新的检测伪影算法来测试使用 2DSTE 分析 LV 旋转变形的可行性。该研究共纳入 20 名健康对照者和 53 名竞技运动员。采用 2DSTE 在胸骨旁短轴切面分析圆周应变(CS)、径向应变(RS)和 LV 旋转。排除潜在伪影的逐步算法首先通过视觉评估图像质量,评估指标为整个心动周期内是否能完整显示所有心肌节段,然后排除存在传导异常的参与者的数据。下一步是优化跟踪区域,并在多个可比较的 cineloop 中交叉检查不合理的应变波形。最后,如果标准失败和 LV 壁跟踪不正确,排除应变曲线中持续存在不合理波形。在 89%(n=73/82)的所有受试者中观察到合理的生理应变曲线。在对照组中,所有不合理的波形都可以确认为伪影。该算法应用于 53 名专业运动员进行测试和验证其可行性。记录到 25 名运动员的 CS 异常波形,其中 22 名运动员因跟踪失败和 3 名运动员因图像采集不正确被确认为伪影。CS 伪影主要位于 LV 基底后外侧节段(心内膜:6%,n=4/70;p<0.05)和基底后段(心内膜:8%,n=5/70;p<0.05)。运动员的胸骨旁短轴切面 2DSTE 分析圆周和径向应变以及 LV 旋转是可行的。所提出的算法有助于避免伪影,并可能有助于该技术的标准化。2DSTE 可能为检测病毒性心肌炎等疾病提供一种有价值的诊断工具,例如在运动员中。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/6e5a/8302535/16571f950651/10554_2021_2213_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验