Department of Medical Surgical-Therapy, Medicine Faculty, Extremadura University, 06006 Badajoz, Spain.
Promoting a Healthy Society Research Group, Faculty of Sport Sciences, University of Extremadura, 10003 Cáceres, Spain.
Int J Environ Res Public Health. 2021 Mar 3;18(5):2489. doi: 10.3390/ijerph18052489.
The joint position sense (JPS) has been used as an indirect marker of proprioception in subjects with non-specific chronic low back pain (NSCLBP), showing impairment in previous studies. It seems necessary to devise reliable tests to measure proprioceptive deficits in subjects with NSLBP. The objective of this study was to analyse the test-retest reliability and smallest real difference (SRD) of lumbar proprioception through the JPS indicator in a sample of patients with NSCLBP. Fifty participants with NSCLBP performed three repetitions of 30° lumbar flexion while standing and sitting using the iPhone inclinometer application to measure the lumbar joint repositioning error. For the reliability analysis, we performed an intra-session test-retest. : The total sample ICC values were excellent for standing (0.96) and sitting (0.93) 30° lumbar flexion. In addition, our results showed that, for the total sample, an SRD < 12% can be considered as a true change in proprioception concerning this procedure. On the other hand, men have better reliability than women in both standing and sitting positions. Additionally, the sitting position has better reliability than the standing position. The standard error of measurement (SEM) percentage was 4.2 for standing and 3.8 for sitting. The SRD percentage was 11.6 for standing and 10.4 for sitting. The iPhone inclinometer seems reliable for assessing proprioceptive ability through the lumbar joint repositioning error in subjects with NSCLBP in both standing (ICC = 0.96) and sitting (ICC = 0.93) positions. This technological device showed a lower measurement error for sitting position (SRD < 12%).
关节位置觉(JPS)已被用作非特异性慢性下腰痛(NSCLBP)患者本体感觉的间接标志物,在之前的研究中显示存在损伤。似乎有必要设计可靠的测试来测量 NSCLBP 患者的本体感觉缺陷。本研究的目的是分析 JPS 指标在 NSCLBP 患者中通过腰椎本体感觉的测试-再测试可靠性和最小真实差异(SRD)。 50 名 NSCLBP 患者使用 iPhone 倾斜计应用程序在站立和坐姿下重复进行 3 次 30°腰椎屈曲,以测量腰椎关节重新定位误差。为了进行可靠性分析,我们进行了一次室内测试-再测试。:站立(0.96)和坐姿(0.93)30°腰椎屈曲的总样本 ICC 值均为优秀。此外,我们的结果表明,对于总样本,SRD < 12%可以被认为是该过程中本体感觉的真实变化。另一方面,男性在站立和坐姿下的可靠性均优于女性。此外,坐姿的可靠性优于站姿。站立时的测量误差百分比(SEM)为 4.2%,坐姿时为 3.8%。站立时的 SRD 百分比为 11.6%,坐姿时为 10.4%。iPhone 倾斜计似乎可用于通过 NSCLBP 患者腰椎关节重新定位误差在站立(ICC = 0.96)和坐姿(ICC = 0.93)位置评估本体感觉能力。这种技术设备在坐姿下显示出较低的测量误差(SRD < 12%)。