Mass testing for early identification and isolation of infectious COVID-19 individuals is efficacious for reducing disease spread. Antigen-detecting rapid diagnostic tests (Ag-RDT) may be suitable for testing strategies; however, benchmark comparisons are scarce.
We used 286 nasopharyngeal specimens from unexposed asymptomatic individuals collected between December 2020 and January 2021 to assess five Ag-RDTs marketed by Abbott, Siemens, Roche Diagnostics, Lepu Medical, and Surescreen.
For the overall sample, the performance parameters of Ag-RDTs were as follows: Abbott assay, sensitivity 38.6% (95%CI 29.1-48.8) and specificity 99.5% (97-100%); Siemens, sensitivity 51.5% (41.3-61.6) and specificity 98.4% (95.3-99.6); Roche, sensitivity 43.6% (33.7-53.8) and specificity 96.2% (92.4-98.5); Lepu, sensitivity 45.5% (35.6-55.8) and specificity 89.2% (83.8-93.3%); Surescreen, sensitivity 28.8% (20.2-38.6) and specificity 97.8% (94.5-99.4%). For specimens with cycle threshold (Ct) <30 in RT-qPCR, all Ag-RDT achieved a sensitivity ≥70%. The modelled negative- and positive-predictive value for 1% prevalence were >99% and <50%, respectively.
When screening unexposed asymptomatic individuals, two Ag-RDTs achieved sensitivity ≥80% for specimens with Ct<30 and specificity ≥96%. The estimated negative predictive value suggests the suitability of Ag-RDTs for mass screenings of SARS-CoV-2 infection in the general population.
大规模检测以早期识别和隔离传染性 COVID-19 个体对于减少疾病传播是有效的。抗原检测快速诊断试验(Ag-RDT)可能适合检测策略;然而,基准比较很少。
我们使用了 286 份来自 2020 年 12 月至 2021 年 1 月期间未暴露的无症状个体的鼻咽拭子,以评估 Abbott、Siemens、Roche Diagnostics、Lepu Medical 和 Surescreen 销售的五种 Ag-RDT。
对于整个样本,Ag-RDT 的性能参数如下:Abbott 检测,敏感性 38.6%(95%CI 29.1-48.8)和特异性 99.5%(97-100%);Siemens,敏感性 51.5%(41.3-61.6)和特异性 98.4%(95.3-99.6%);Roche,敏感性 43.6%(33.7-53.8)和特异性 96.2%(92.4-98.5%);Lepu,敏感性 45.5%(35.6-55.8)和特异性 89.2%(83.8-93.3%);Surescreen,敏感性 28.8%(20.2-38.6)和特异性 97.8%(94.5-99.4%)。对于 RT-qPCR 中 Ct<30 的标本,所有 Ag-RDT 的敏感性均≥70%。在 1%流行率下,阴性和阳性预测值分别为>99%和<50%。
当筛查未暴露的无症状个体时,两种 Ag-RDT 在 Ct<30 的标本中达到了≥80%的敏感性和≥96%的特异性。估计的阴性预测值表明,Ag-RDT 适合在普通人群中对 SARS-CoV-2 感染进行大规模筛查。