Imaging technologies have been developed to assist physicians and dentists in detecting various diseases. Photoacoustic imaging (PAI) is a new technique that shows great applicability to soft tissues. This study aimed to investigate the effect of diode laser intensity modulation on photoacoustic (PA) image quality. The prototype of the PAI system in this study utilized a non-ionizing 532 nm continuouswave (CW) diode laser illumination. Samples in this study were oral soft tissues of Sprague-Dawley rats fixed in 10% formalin solution. PA images were taken ex vivo by using the PAI system. The laser exposure for oral soft tissue imaging was set in various duty cycles (16%, 24%, 31%, 39%, and 47%). The samples were embedded in paraffin, and PA images were taken from the paraffinembedded tissue blocks in a similar method by using duty cycles of 40%, 45%, 50%, 55%, 60% respectively to reveal the influence of the laser duty cycle on PA image quality. The oral soft tissue is clearly shown as a yellow to red area in PA images, whereas the nonbiological material appears as a blue background. The color of the PA image is determined by the PA intensity. Hence, the PA intensity of oral soft tissue was generally higher than that of the nonbiological material around it. The Kruskal-Wallis test followed by Mann-Whitney post-hoc analysis revealed significant differences (<0.05) in the quality of PA images produced by using a 16%-47% duty cycle of laser intensity modulation for direct imaging of oral soft tissue fixed in 10% formalin solution. The PA image quality of paraffin-embedded tissue was higher than that of direct oral soft tissue images, but no significant differences in PA image quality were found between the groups. The PAI system built in this study can image oral soft tissue. The sample preparation and the diode laser intensity modulation may influence the PA image quality for oral soft tissue imaging. Nonetheless, the influence of diode laser intensity modulation is not significant for the PA image quality of paraffin-embedded tissue.
成像技术已得到发展,以协助医生和牙医检测各种疾病。光声成像(PAI)是一种对软组织具有很大适用性的新技术。本研究旨在探讨二极管激光强度调制对光声(PA)图像质量的影响。本研究中PAI系统的原型采用非电离532nm连续波(CW)二极管激光照明。本研究中的样本是固定在10%福尔马林溶液中的Sprague-Dawley大鼠的口腔软组织。通过使用PAI系统在体外拍摄PA图像。口腔软组织成像的激光曝光设置为不同的占空比(16%、24%、31%、39%和47%)。样本被嵌入石蜡中,并通过分别使用40%、45%、50%、55%、60%的占空比以类似方法从石蜡包埋的组织块中拍摄PA图像,以揭示激光占空比对PA图像质量的影响。在PA图像中,口腔软组织清晰显示为黄色至红色区域,而非生物材料则呈现为蓝色背景。PA图像的颜色由PA强度决定。因此,口腔软组织的PA强度通常高于其周围非生物材料的PA强度。采用Kruskal-Wallis检验并随后进行Mann-Whitney事后分析,结果显示,对于固定在10%福尔马林溶液中的口腔软组织直接成像,使用16%-47%占空比的激光强度调制所产生的PA图像质量存在显著差异(<0.05)。石蜡包埋组织的PA图像质量高于口腔软组织直接图像,但各组之间PA图像质量未发现显著差异。本研究构建的PAI系统能够对口腔软组织进行成像。样本制备和二极管激光强度调制可能会影响口腔软组织成像的PA图像质量。尽管如此,二极管激光强度调制对石蜡包埋组织的PA图像质量影响不显著。