Suppr超能文献

由四个边缘线位置的牙体预备制作的临时冠的边缘和内部适合性以及凹面表面平整度。

Marginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparation of four finish line locations.

作者信息

Son Keunbada, Son Young-Tak, Lee Ji-Min, Lee Kyu-Bok

机构信息

Department of Dental Science, Graduate School, Kyungpook National University, Daegu, Republic of Korea.

Advanced Dental Device Development Institute, Kyungpook National University, Daegu, Republic of Korea.

出版信息

Sci Rep. 2021 Jul 6;11(1):13947. doi: 10.1038/s41598-021-93455-7.

Abstract

This study evaluated the marginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparation scanned at four finish line locations. The right maxillary first molar tooth preparation model was fabricated using a ceramic material and placed in four finish line locations (supragingival, equigingival, subgingival, and subgingival with a cord). Intraoral scanning was performed. Crowns were designed based on the scanned area. Interim crowns were fabricated using a stereolithography three-dimensional (3D) printer (N = 16 per location). Marginal and internal fit were evaluated with a silicone replica technique. Intaglio surface trueness was evaluated using a 3D inspection software. One-way analysis of variance and Tukey HSD test were performed for comparisons (α = 0.05). The marginal and internal fit showed significant differences according to locations (P < 0.05); the marginal fit showed the best results in the supragingival finish line (P < 0.05). Intaglio surface trueness was significantly different in the marginal region, with the highest value in the subgingival location (P < 0.05). Crowns fabricated on the subgingival finish line caused inaccurate marginal fit due to poor fabrication reproducibility of the marginal region. The use of an intraoral scanner should be decided on the clinical situation and needs.

摘要

本研究评估了在四个肩台位置扫描牙体预备后制作的临时冠的边缘适合性、内部适合性和凹面表面精度。使用陶瓷材料制作右上颌第一磨牙牙体预备模型,并将其置于四个肩台位置(龈上、龈齐、龈下以及放置龈线后的龈下)。进行口内扫描。基于扫描区域设计全冠。使用立体光刻三维(3D)打印机制作临时冠(每个位置N = 16)。采用硅橡胶复制技术评估边缘适合性和内部适合性。使用3D检测软件评估凹面表面精度。进行单因素方差分析和Tukey HSD检验以进行比较(α = 0.05)。边缘适合性和内部适合性根据位置显示出显著差异(P < 0.05);边缘适合性在龈上肩台处显示出最佳结果(P < 0.05)。凹面表面精度在边缘区域存在显著差异,龈下位置的值最高(P < 0.05)。在龈下肩台制作的全冠由于边缘区域制作的可重复性差而导致边缘适合性不准确。应根据临床情况和需求决定是否使用口内扫描仪。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/d1cf/8260589/927e7a490346/41598_2021_93455_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验