Hassan Alaa Thabet, Ahmed Soher Mostafa, AbdelHaffeez Azza Salah, Mohamed Sherif A A
Department of Chest Diseases and Tuberculosis.
Department of Internal Medicine.
Multidiscip Respir Med. 2021 Jul 6;16(1):742. doi: 10.4081/mrm.2021.742. eCollection 2021 Jan 15.
Despite its wide use in clinical practice, few studies have assessed the role of pulse oximetry in patients with heart failure. We aimed to evaluate the accuracy and precision of the pulse oximeter in patients with heart failure and to determine this accuracy at three different sensor locations.
Comparison of pulse oximetry reading (SpO) with arterial oxygen saturation (SaO) was reported in 3 groups of patients with heart failure (HF); those with ejection fraction (EF) >40%, those with EF <40%, and those with acute HF (AHF) with ST and non-ST segment elevation acute myocardial infarction (STEMI and non-STEMI).
A total of 235 patients and 90 control subjects were enrolled. There were significant differences in O saturation between control and patients' groups when O saturation is measured at the finger and toe, but not the ear probes; p=0.029, p=0.049, and 0.051, respectively. In HF with EF>40% and AHF with O saturations >90%, finger oximetry is the most accurate and reliable, while in HF with EF<40% and in patients with AHF with O saturations <90%, ear oximetry is the most accurate.
Pulse oximetry is a reliable tool in assessing oxygen saturation in patients with heart failure of different severity. In HF with EF>40% and in AHF with O saturations >90%, finger oximetry is the most accurate and reliable, while in HF with EF<40% and in patients with AHF with O saturations <90%, ear oximetry is the most accurate. Further studies are warranted.
尽管脉搏血氧饱和度测定法在临床实践中被广泛应用,但很少有研究评估其在心力衰竭患者中的作用。我们旨在评估脉搏血氧仪在心力衰竭患者中的准确性和精确性,并确定在三个不同传感器位置的准确性。
报告了3组心力衰竭(HF)患者的脉搏血氧饱和度读数(SpO)与动脉血氧饱和度(SaO)的比较;射血分数(EF)>40%的患者、EF<40%的患者以及伴有ST段和非ST段抬高急性心肌梗死(STEMI和非STEMI)的急性心力衰竭(AHF)患者。
共纳入235例患者和90例对照受试者。当在手指和脚趾测量血氧饱和度时,对照组与患者组之间存在显著差异,但在耳部探头测量时无显著差异;p值分别为0.029、0.049和0.051。在EF>40%的心力衰竭患者和血氧饱和度>90%的急性心力衰竭患者中,手指血氧测定法最准确可靠,而在EF<40%的心力衰竭患者和血氧饱和度<90%的急性心力衰竭患者中,耳部血氧测定法最准确。
脉搏血氧饱和度测定法是评估不同严重程度心力衰竭患者血氧饱和度的可靠工具。在EF>40%的心力衰竭患者和血氧饱和度>90%的急性心力衰竭患者中,手指血氧测定法最准确可靠,而在EF<40%的心力衰竭患者和血氧饱和度<90%的急性心力衰竭患者中,耳部血氧测定法最准确。有必要进行进一步研究。