Chen Tiffany A, Li Jonathan, Schallhorn Julie M, Sun Catherine Q
Department of Ophthalmology, University of California San Francisco, San Francisco, CA, USA.
F.I Proctor Foundation, University of California San Francisco, San Francisco, CA, USA.
Clin Ophthalmol. 2021 Jul 28;15:3205-3211. doi: 10.2147/OPTH.S309727. eCollection 2021.
To evaluate the agreement of a home vision screening test compared to standard in-office technician-measured Snellen visual acuity to allow for remote screening and triaging of patients.
In this prospective study, English-speaking patients with in-office ophthalmology appointments from May to August 2020 and visual acuity better than 20/125 were asked to complete a home vision test one week before their scheduled in-office appointment. The home vision test was a modified ETDRS chart displayed in a PDF document that could be printed or viewed on a monitor. The primary outcome was the mean difference between office-based and home visual acuity.
Eighty-two eyes of 45 patients were included in the study with 45 study eyes analyzed. The mean difference between office-based and home visual acuity was -0.02 logMAR (SD 0.15, =0.28) among study eyes. Of these eyes, 91% demonstrated agreement between the two methods within 0.2 logMAR of the mean difference, and 60% had agreement within 0.1 logMAR of the mean difference. There were no significant demographic or ocular risk factors leading to a greater difference between the tests.
There was good agreement between the home and in-office Snellen tests for patients with vision better than 20/125. The home vision test can be used to remotely determine if there is a significant vision change of >0.2 logMAR or approximately 2 lines of visual acuity.
评估一种家庭视力筛查测试与标准的办公室技术人员测量的斯内伦视力之间的一致性,以便对患者进行远程筛查和分诊。
在这项前瞻性研究中,2020年5月至8月预约在办公室进行眼科检查且视力优于20/125的英语患者,被要求在预定的办公室检查前一周完成一项家庭视力测试。家庭视力测试是一个以PDF文档形式呈现的改良ETDRS视力表,可以打印或在显示器上查看。主要结果是办公室视力与家庭视力之间的平均差异。
45名患者的82只眼睛纳入研究,其中45只研究眼进行了分析。研究眼中办公室视力与家庭视力的平均差异为-0.02 logMAR(标准差0.15,P=0.28)。在这些眼睛中,91%的眼睛在平均差异的0.2 logMAR范围内两种方法显示一致,60%的眼睛在平均差异的0.1 logMAR范围内一致。没有显著的人口统计学或眼部危险因素导致测试之间的差异更大。
对于视力优于20/125的患者,家庭斯内伦测试与办公室测试之间有良好的一致性。家庭视力测试可用于远程确定是否存在>0.2 logMAR或约2行视力的显著视力变化。