Department of Optometry and Vision Science, University of Auckland, Auckland, New Zealand.
BMJ Open. 2013 Jun 20;3(6):e002730. doi: 10.1136/bmjopen-2013-002730.
Visual acuity is a common measurement in general practice, and the advent of new technology such as tablet computers offers a change in the way in which these tests are delivered. The aim of this study was to assess whether measurements of distance visual acuity using LogMAR letter charts displayed on an iPad tablet computer were in agreement with standard clinical tests of visual acuity in adults with normal vision.
Blinded, diagnostic test study.
Single centre (University) in Auckland, New Zealand.
University staff and students (n=85). Participants were required to have visual acuity better than 6/60 and wear habitual refractive correction during testing. Participants were excluded if there was any history of ocular pathology.
Visual acuity measured under a number of conditions.
The iPad tablet with its glossy screen was highly susceptible to glare resulting in acuity measurements that were significantly poorer (approximately 2 LogMAR lines) than those made using an ETDRS chart and a standard computerised testing system (n=56). However, fitting the iPad with an antiglare screen and positioning the device away from sources creating reflected (veiling) glare resulted in acuity measurements that were equivalent those made using gold standard charts (n=29).
Tablet computers are an attractive option for visual acuity measurement due to portability, the ability to randomise letters, automated scoring of acuity and the ability to select from a range of charts. However, these devices are only suitable for use in situations where sources of glare can be eliminated.
视力是一般实践中的常见测量指标,而平板电脑等新技术的出现改变了这些测试的提供方式。本研究旨在评估在 iPad 平板电脑上显示的 LogMAR 字母图表测量距离视力时,是否与正常视力成年人的标准临床视力测试结果一致。
盲法、诊断测试研究。
新西兰奥克兰的单一中心(大学)。
大学工作人员和学生(n=85)。参与者需要有优于 6/60 的视力,并在测试时佩戴习惯性矫正视力。如果有任何眼部病史,则将参与者排除在外。
在多种条件下测量的视力。
由于反光,iPad 平板电脑的光泽屏幕非常容易受到眩光的影响,导致视力测量结果明显较差(约 2 个 LogMAR 线),而使用 ETDRS 图表和标准计算机测试系统(n=56)进行的测量结果则要好得多。然而,为 iPad 配备防眩光屏幕并将设备远离产生反射(掩蔽)眩光的光源,可以使视力测量结果与使用黄金标准图表(n=29)时相当。
由于便携性、随机字母的能力、视力自动评分以及能够从一系列图表中进行选择,平板电脑是视力测量的一个有吸引力的选择。然而,这些设备仅适用于可以消除眩光源的情况。