Predictive Equation for Angle Opening Distance at 750 μm After Laser Peripheral Iridotomy in Primary Angle Closure Suspects.

作者信息

Gao Xinbo, Zhou Yuying, Zuo Chengguo, Chen Liming, Ren Jiawei, Lin Huishan, Liao Yunru, Gong Haijun, Hu Huanling, Lin Mingkai

机构信息

State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China.

出版信息

Front Med (Lausanne). 2021 Aug 12;8:715747. doi: 10.3389/fmed.2021.715747. eCollection 2021.

Abstract

The aim of this study was to investigate the changes in anterior segment parameters as assessed by ultrasound biomicroscopy (UBM) after laser peripheral iridotomy (LPI) and to propose a prediction equation for the width of the angle after LPI. This was a prospective study. The participants included 100 subjects with primary angle closure suspect (PACS). Anterior segment UBM parameters were measured, whereas AOD750 was chosen to indicate the width of the angle associated with gonioscopic angle closure, as found in a prior study. Angle parameters, iris parameters, anterior chamber parameters and ciliary body parameters. All angle parameters increased after LPI, including the mean angle opening distance at 750 μm (AOD750), mean angle opening distance at 500 μm from the scleral spur (AOD500), mean angle opening distance at 750 μm from the scleral spur (AOD750), and mean angle recess area at 750 μm from the scleral spur (ARA750). Among iris parameters and ciliary body parameters, the iris thickness at 2,000 μm (IT2000), iris curvature (IC), and trabecular-ciliary process distance (ICPD) were reduced after LPI. The final equation consisted of four parameters: anterior chamber depth (ACD), iris thickness at 750 μm from the scleral spur (IT750), AOD750, and lens vault (LV). This equation explained 42.7% of the variability in the angle opening indicator AOD750 after LPI, whereas in the plateau iris configuration subgroup, the accuracy of the prediction equation reached the highest a maximum of 68.6%. There was an increase in angle opening and iris flattening after LPI. An equation involving four angle parameters was constructed, this equation which could explained 42.7% of the variability in the angle opening indicator AOD750 after LPI whereas in the plateau iris configuration subgroup, the accuracy of the prediction equation reached a maximum of 68.6%.

摘要

本研究的目的是通过超声生物显微镜(UBM)研究激光周边虹膜切开术(LPI)后眼前节参数的变化,并提出LPI后房角宽度的预测方程。这是一项前瞻性研究。参与者包括100名原发性房角关闭可疑(PACS)患者。测量了眼前节UBM参数,而如先前研究中所发现的,选择AOD750来表示与前房角镜检查房角关闭相关的房角宽度。房角参数、虹膜参数、前房参数和睫状体参数。LPI后所有房角参数均增加,包括距巩膜突750μm处的平均房角开放距离(AOD750)、距巩膜突500μm处的平均房角开放距离(AOD500)、距巩膜突750μm处的平均房角开放距离(AOD750)以及距巩膜突750μm处的平均房角隐窝面积(ARA750)。在虹膜参数和睫状体参数中,LPI后距巩膜突2000μm处的虹膜厚度(IT2000)、虹膜曲率(IC)和小梁-睫状体距离(ICPD)降低。最终方程由四个参数组成:前房深度(ACD)、距巩膜突750μm处的虹膜厚度(IT750)、AOD750和晶状体拱高(LV)。该方程解释了LPI后房角开放指标AOD750变异性的42.7%,而在高褶虹膜构型亚组中,预测方程的准确性最高达到68.6%。LPI后房角开放增加且虹膜变平。构建了一个涉及四个房角参数的方程,该方程可解释LPI后房角开放指标AOD750变异性的42.7%,而在高褶虹膜构型亚组中,预测方程的准确性最高达到68.6%。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/2b09/8387715/de343a961bf9/fmed-08-715747-g0001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验