CLINICAL RELEVANCE

Accurate measurement of the anterior chamber depth is very important. There is no report regarding the agreement between rotating Scheimpflug imaging (Pentacam HR) and biograph (Lenstar LS 900) in children. This study therefore explores the agreement between Pentacam and Biograph in measuring anterior chamber depth in children.

BACKGROUND

This study aims to determine the agreement between Pentacam and Biograph in measuring anterior chamber depth in children.

METHODS

The participants were students living in urban and rural areas of Shahroud, Iran, selected through cluster sampling. The students were transported to the examination site to undergo imaging and optometric tests. Pentacam imaging was then conducted, and biograph was used to measure biometric components. In this report, the anterior chamber depth was calculated from the corneal endothelium.

RESULTS

Of 6624 students selected randomly, 5620 participated in the study. After applying the exclusion criteria, 4882 eyes were included in the final analysis. The mean anterior chamber depth measured by the Pentacam (3.09 ± 0.26 mm) was higher than that of biograph (3.04 ± 0.24 mm) (p < 0.001). The 95% limit of agreement (LOA) between the two devices was -0.19 to 0.09 mm. The variation of the difference between the two devices decreased, LOA became narrower, and the correlation coefficient of the devices increased with ageing. The highest intraclass correlation coefficient was seen among myopic (0.974) participants. The 95% LOA was -0.20 to 0.12 mm in hyperopic, -0.17 to 0.07 mm in myopic and -0.19 to 0.09 mm in emmetropic participants.

CONCLUSION

The Pentacam and Biograph can be used interchangeably for measuring the anterior chamber depth in children.

摘要

临床相关性

准确测量前房深度非常重要。目前尚无关于旋转 Scheimpflug 成像(Pentacam HR)和生物测量仪(Lenstar LS 900)在儿童中测量前房深度的一致性的报道。因此,本研究旨在探讨 Pentacam 和 Biograph 在测量儿童前房深度方面的一致性。

背景

本研究旨在确定 Pentacam 和 Biograph 在测量儿童前房深度方面的一致性。

方法

通过整群抽样选择居住在伊朗沙赫鲁德城乡地区的学生作为研究对象。将学生运送到检查现场进行成像和验光测试。然后进行 Pentacam 成像,并用生物测量仪测量生物测量参数。在本报告中,前房深度是从角膜内皮计算得出的。

结果

在随机选择的 6624 名学生中,有 5620 名学生参加了研究。在应用排除标准后,最终有 4882 只眼纳入最终分析。Pentacam 测量的平均前房深度(3.09±0.26 mm)高于生物测量仪(3.04±0.24 mm)(p<0.001)。两种设备之间的 95%一致性界限(LOA)为-0.19 至 0.09 mm。两种设备之间的差值变异减小,LOA 变窄,且设备的相关系数随年龄增长而增加。在近视者中观察到最高的组内相关系数(0.974)。远视者的 95% LOA 为-0.20 至 0.12 mm,近视者为-0.17 至 0.07 mm,正视者为-0.19 至 0.09 mm。

结论

Pentacam 和 Biograph 可在儿童中互换用于测量前房深度。