Suppr超能文献

不同牙弓宽度对三种口腔内扫描仪准确性的影响。

Effect of different arch widths on the accuracy of three intraoral scanners.

作者信息

Kaewbuasa Narin, Ongthiemsak Chakree

机构信息

Department of Prosthetic Dentistry, Faculty of Dentistry, Prince of Songkla University, Hat Yai, Songkhla, Thailand.

出版信息

J Adv Prosthodont. 2021 Aug;13(4):205-215. doi: 10.4047/jap.2021.13.4.205. Epub 2021 Aug 26.

Abstract

PURPOSE

The purpose of this study was to compare the accuracy of three intraoral scanner (IOS) systems with three different dental arch widths.

MATERIALS AND METHODS

Three dental models with different intermolar widths (small, medium, and large) were attached to metal bars of different lengths (30, 40, and 50 mm). The bars were measured with a coordinate measuring machine and used as references. Three IOSs were compared: TRIOS 3 (TRI), True Definition (TD), and Dental Wings (DW). The relative length and angular deviation of both ends of the metal bars from the scan data set (n = 15) were calculated and analyzed.

RESULTS

Comparing among scanners in terms of trueness, the relative length deviation of DW in the small (1.28%) and medium (1.08%) arches were significantly higher than TRI (0.46% and 0.48%) and TD (0.33% and 0.18%). The angular deviation of DW in the small (1.75°) and medium (1.83°) arches were also significantly greater than TRI (0.63° and 0.40°) and TD (0.55° and 0.89°). Comparing within scanner, the large arch of DW showed better accuracy than other arch sizes ( < .05). On the other hand, the larger arch of TD presented a greater tendency of angular deviation in terms of trueness. No significant differences were found in terms of trueness between the arch widths of TRI group.

CONCLUSION

The different widths of the dental arches can affect the accuracy of some intraoral scanners in full arch scan.

摘要

目的

本研究旨在比较三种口内扫描仪(IOS)系统在三种不同牙弓宽度下的准确性。

材料与方法

将三个具有不同磨牙间宽度(小、中、大)的牙科模型附着在不同长度(30、40和50毫米)的金属棒上。用坐标测量机对金属棒进行测量并用作参考。比较了三种IOS:TRIOS 3(TRI)、True Definition(TD)和Dental Wings(DW)。计算并分析了扫描数据集(n = 15)中金属棒两端的相对长度和角度偏差。

结果

在准确性方面比较扫描仪,DW在小牙弓(1.28%)和中牙弓(1.08%)中的相对长度偏差显著高于TRI(0.46%和0.48%)和TD(0.33%和0.18%)。DW在小牙弓(1.75°)和中牙弓(1.83°)中的角度偏差也显著大于TRI(0.63°和0.40°)和TD(0.55°和0.89°)。在扫描仪内部比较,DW的大牙弓显示出比其他牙弓尺寸更好的准确性(<.05)。另一方面,TD的大牙弓在准确性方面呈现出更大的角度偏差趋势。TRI组牙弓宽度之间在准确性方面未发现显著差异。

结论

牙弓宽度的不同会影响全牙弓扫描中一些口内扫描仪的准确性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/e8a0/8410304/3ed9e297c2cb/jap-13-205-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验