Abstract

The World Health Organization has presented their recommendations for energy expenditure to improve public health. Activity trackers do represent a modern solution for measuring physical activity, particularly in terms of steps/day and energy expended in physical activity (active energy expenditure). According to the manufacturer's instructions, these activity trackers can be placed on different body locations, mostly at the wrist and the hip, in an undifferentiated manner. The objective of this study was to compare the absolute error rate of active energy expenditure measured by a wrist-worn and hip-worn ActiGraph GT3X+ over a 24-h period in free-living conditions in young and older adults. Over the period of a 24-h period, 22 young adults and 22 older adults were asked to wear two ActiGraph GT3X+ at two different body locations recommended by the manufacturer, namely one around the wrist and one above the hip. Freedson algorithm was applied for data analysis. For both groups, the absolute error rate tended to decrease from 1,252 to 43% for older adults and from 408 to 46% for young participants with higher energy expenditure. Interestingly, for both young and older adults, the wrist-worn ActiGraph provided a significantly higher values of active energy expenditure (943 ± 264 cal/min) than the hip-worn (288 ± 181 cal/min). Taken together, these results suggest that caution is needed when using active energy expenditure as an activity tracker-based metric to quantify physical activity.

摘要

世界卫生组织已提出其关于能量消耗的建议,以改善公众健康。活动追踪器确实是测量身体活动的一种现代解决方案,特别是在每日步数和身体活动中消耗的能量(活动能量消耗)方面。根据制造商的说明,这些活动追踪器可以无差别地放置在身体的不同部位,主要是手腕和臀部。本研究的目的是比较在自由生活条件下,年轻人和老年人佩戴在手腕和臀部的ActiGraph GT3X+在24小时内测量的活动能量消耗的绝对误差率。在24小时期间,22名年轻人和22名老年人被要求按照制造商推荐的两个不同身体部位佩戴两个ActiGraph GT3X+,即一个戴在手腕上,一个戴在臀部上方。采用Freedson算法进行数据分析。对于两组而言,随着能量消耗增加,老年人的绝对误差率从1252降至43%,年轻参与者从408降至46%。有趣的是,对于年轻人和老年人来说,佩戴在手腕上的ActiGraph测量的活动能量消耗值(943±264卡路里/分钟)显著高于佩戴在臀部的(288±181卡路里/分钟)。综上所述,这些结果表明,在将活动能量消耗作为基于活动追踪器的指标来量化身体活动时需要谨慎。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3cb2/8438201/fe98745aa1ca/fmed-08-696968-g0001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验