Suppr超能文献

等离子体处理过氧氢雾化消毒在各种医院环境中的有效性。

Effectiveness of Plasma-Treated Hydrogen Peroxide Mist Disinfection in Various Hospital Environments.

机构信息

Department of Biomedical Engineering, Hanyang University, Seoul 04763, Korea.

Department of Laboratory Medicine, College of Medicine, Hanyang University, Seoul 04763, Korea.

出版信息

Int J Environ Res Public Health. 2021 Sep 18;18(18):9841. doi: 10.3390/ijerph18189841.

Abstract

Hospital environments are associated with a high risk of infection. As plasma-treated hydrogen peroxide mist disinfection has a higher disinfection efficacy, we tested the efficacy of plasma-treated hydrogen peroxide mist disinfection on several surfaces in various hospital environments. Disinfection was performed in 23 rooms across different hospital environments, including hospital wards, outpatient departments (OPDs), and emergency rooms. A total of 459 surfaces were swabbed before/after disinfection. Surfaces were also divided into plastic, metal, wood, leather, ceramic, silicone, and glass for further analyses. Only gram-positive bacteria were statistically analyzed because the number of gram-negative bacteria and mold was insufficient. Most colony-forming units (CFUs) of gram-positive bacteria were observed in OPDs and on leather materials before disinfection. The proportion of surfaces that showed a percentage decrease in CFU values of more than 90% after disinfection were as follows: OPDs (85%), hospital wards (99%), and emergency rooms (100%); plastic (97%), metal (83%), wood (84%), leather (81%), and others (87%). Plasma-treated hydrogen peroxide mist disinfection resulted in a significant decrease in the CFU values of gram-positive bacteria in various environments. Plasma-treated hydrogen peroxide mist disinfection is an effective and efficient method of disinfecting various hospital environments.

摘要

医院环境具有较高的感染风险。由于等离子体处理过的过氧化氢雾化消毒具有更高的消毒效果,我们测试了等离子体处理过的过氧化氢雾化消毒在各种医院环境下对多种表面的消毒效果。在不同的医院环境中,共对 23 个房间进行了消毒,包括医院病房、门诊部(OPD)和急诊室。在消毒前后共对 459 个表面进行了拭子采样。还将表面分为塑料、金属、木材、皮革、陶瓷、硅橡胶和玻璃进行进一步分析。由于革兰氏阴性菌和霉菌的数量不足,仅对革兰氏阳性菌进行了统计分析。在消毒前,OPD 中以及皮革材料上的革兰氏阳性菌的菌落形成单位(CFU)数量最多。消毒后 CFU 值减少 90%以上的表面比例如下:OPD(85%)、医院病房(99%)和急诊室(100%);塑料(97%)、金属(83%)、木材(84%)、皮革(81%)和其他(87%)。等离子体处理过的过氧化氢雾化消毒可显著降低各种环境中的革兰氏阳性菌 CFU 值。等离子体处理过的过氧化氢雾化消毒是一种有效且高效的消毒各种医院环境的方法。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/9175/8467658/37ec5e321e39/ijerph-18-09841-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验