Kashefimehr Atabak, Rahbar Mahdi, Faramarzi Masoumeh, Babaloo Amirreza, Sadighi Mehrnoosh, Goshaderoo Abbas
Dental and Periodontal Research Center, Department of Periodontics, Dental School, Tabriz University of Medical Sciences, Tabriz, Iran.
Department of Restorative Dentistry, School of Dentistry, Ardabil University of Medical Sciences, Ardabil, Iran.
Maedica (Bucur). 2021 Jun;16(2):223-229. doi: 10.26574/maedica.2021.16.2.223.
The high success rate of implants has made implant-based prostheses attractive to edentulous patients. Osseointegration lasts 4-6 months, increasing to 6-8 months in cases requiring bone grafts and guided bone regeneration. Many efforts have been made to accelerate osseointegration, including low level laser (LLL) and light emitting diode (LED) photobiomodulation. Twelve patients underwent bimaxillary immediate implant surgery with particulate bone grafts between the socket wall and the implant, and the transmucosal abutment was attached on implants at the same time. The intervention side was exposed to LED radiation for 20 minutes a day one day preoperatively and 10 consecutive sessions, starting from the day of surgery. A trained operator measured and recorded the implant stability quotient (ISQ) value on both sides immediately after surgery as well as one month and three months postoperatively. The ISQ value was 37.54 on the non-irradiated side immediately after surgery; it decreased to 35.09 one month postoperatively and increased to 46.45 at three months after the operation. The ISQ value was 36.73 on the irradiated side immediately after surgery and it increased to 47.36 and 71.18 at one month and three months postoperatively, respectively. There were significant differences between the ISQ values on the irradiated side at all the three time intervals, but also a significant difference on the non-irradiated side, except for two other two time intervals of immediately and one month after surgery. Although there was no significant difference between the two sides in terms of the ISQ value immediately after surgery, the ISQ value was significantly higher on the irradiated versus non-irradiated side at one month and three months postoperatively. Low level laser radiation resulted in a favorable increase in the ISQ value in three months. Light emitting diode has lso led to a clinically significant increase in the ISQ value after three months because implants with ISQ values >54 could be loaded.
种植体的高成功率使基于种植体的修复体对无牙患者具有吸引力。骨整合持续4至6个月,在需要骨移植和引导骨再生的情况下会延长至6至8个月。人们已经做出了许多努力来加速骨整合,包括低强度激光(LLL)和发光二极管(LED)光生物调节。12名患者接受了双颌即刻种植手术,在牙槽窝壁与种植体之间植入颗粒状骨移植材料,并同时在种植体上连接穿龈基台。干预侧在术前一天每天接受20分钟的LED照射,并从手术当天开始连续照射10次。一名经过培训的操作人员在术后即刻以及术后1个月和3个月测量并记录两侧的种植体稳定性商数(ISQ)值。术后即刻,未照射侧的ISQ值为37.54;术后1个月降至35.09,术后3个月升至46.45。术后即刻,照射侧的ISQ值为36.73,术后1个月和3个月分别升至47.36和71.18。在所有三个时间间隔内,照射侧的ISQ值均存在显著差异,未照射侧除术后即刻和术后1个月这两个时间间隔外也存在显著差异。虽然术后即刻两侧的ISQ值没有显著差异,但术后1个月和3个月时,照射侧的ISQ值显著高于未照射侧。低强度激光照射在三个月内使ISQ值有了有利的增加。发光二极管在三个月后也使ISQ值有了临床上显著的增加,因为ISQ值>54的种植体可以进行加载。