The objective is to determine, by systematic review, the reliability of testing methods for diagnosis of diabetes-related peripheral neuropathy (DPN) as recommended by the most recent guidelines from the International Diabetes Foundation, International Working Group on the Diabetic Foot and American Diabetes Association. Electronic searches of Cochrane Library, EBSCO Megafile Ultimate and EMBASE were performed to May 2021. Articles were included if they reported on the reliability of recommended chairside tests in diabetes cohorts. Quality appraisal was performed using a Quality Appraisal of Reliability Studies checklist and where possible, meta-analyses, with reliability reported as estimated Cohen's kappa (95% CI). Seventeen studies were eligible for inclusion. Pooled analysis found acceptable inter-rater reliability of vibration perception threshold (VPT) (κ=0.61 (0.50 to 0.73)) and ankle reflex testing (κ=0.60 (0.55 to 0.64)), but weak inter-rater reliability for pinprick (κ=0.45 (0.22 to 0.69)) and 128 Hz tuning fork (κ=0.42 (0.15 to 0.70)), though intra-rater reliability of the 128 Hz tuning fork was moderate (κ=0.54 (0.37 to 0.73)). Inter-rater reliability of the four-site monofilament was acceptable (κ=0.61 (0.45 to 0.77)). These results support the clinical use of VPT, ankle reflexes and four-site monofilament for screening and ongoing monitoring of DPN as recommended by the latest guidelines. The reliability of temperature perception, pinprick, proprioception, three-site monofilament and Ipswich touch test when performed in people with diabetes remains unclear.
目的是通过系统评价,确定国际糖尿病基金会、国际糖尿病足工作组和美国糖尿病协会最近指南推荐的糖尿病相关周围神经病(DPN)诊断检测方法的可靠性。我们对 Cochrane 图书馆、EBSCO Megafile Ultimate 和 EMBASE 进行了电子检索,检索时间截至 2021 年 5 月。如果文章报告了推荐的糖尿病队列床边检查的可靠性,则将其纳入。使用可靠性研究质量评估清单进行质量评估,如果可能,还进行荟萃分析,可靠性以估计的 Cohen's kappa(95%CI)报告。有 17 项研究符合纳入标准。汇总分析发现振动感觉阈值(VPT)(κ=0.61(0.50 至 0.73))和踝反射测试(κ=0.60(0.55 至 0.64))的观察者间可靠性可接受,但针刺痛觉(κ=0.45(0.22 至 0.69))和 128 Hz 音叉(κ=0.42(0.15 至 0.70))的观察者间可靠性较弱,而 128 Hz 音叉的观察者内可靠性为中度(κ=0.54(0.37 至 0.73))。四部位单丝的观察者间可靠性可接受(κ=0.61(0.45 至 0.77))。这些结果支持最新指南推荐的 VPT、踝反射和四部位单丝用于 DPN 的筛查和持续监测的临床应用。在糖尿病患者中进行温度感知、针刺痛觉、本体感觉、三部位单丝和 Ipswich 触觉测试的可靠性仍不清楚。