Suppr超能文献

革兰氏阴性杆菌快速半自动鉴定系统的协同评估:Quantum II BID

A collaborative evaluation of a rapid, semi-automated identification system for gram-negative bacilli: the Quantum II BID.

作者信息

Stevens M, Henrichsen C, Smith M

出版信息

J Med Microbiol. 1986 Mar;21(2):145-50. doi: 10.1099/00222615-21-2-145.

Abstract

The recently-introduced semi-automated bacterial identification system, the Quantum II BID, is designed to identify fermentative and non-fermentative gram-negative bacilli in 4-5 h. The system was evaluated independently by the two participating laboratories. Inter-laboratory reproducibility was determined by testing 181 strains in each laboratory and found to be 97.8%. A further 893 organisms, comprising 417 fresh clinical isolates and 476 stock cultures, were then tested by the system in the two laboratories. Of the fresh clinical isolates, 95.7% yielded the same result as the comparative system used (API 20E) and 93.1% of the stock strains were assigned to their expected, previously established identity. Overall agreement between the two systems for all strains examined was 94.3%. There was no significant statistical difference between the results obtained in the two laboratories.

摘要

最近推出的半自动细菌鉴定系统——Quantum II BID,旨在在4至5小时内鉴定发酵型和非发酵型革兰氏阴性杆菌。该系统由两个参与实验室独立评估。通过在每个实验室测试181株菌株来确定实验室间的再现性,结果发现为97.8%。然后,该系统在两个实验室对另外893株微生物进行了测试,其中包括417株新鲜临床分离株和476株储备培养物。在新鲜临床分离株中,95.7%产生的结果与所使用的对照系统(API 20E)相同,93.1%的储备菌株被鉴定为其预期的、先前确定的身份。对于所有检测菌株,两个系统之间的总体一致性为94.3%。两个实验室获得的结果之间没有显著的统计学差异。