Kozakiewicz Marcin, Gabryelczak Izabela
Department of Maxillofacial Surgery, Medical University of Lodz, 113 Żeromskiego Str., 90-549 Lodz, Poland.
Materials (Basel). 2022 Mar 17;15(6):2230. doi: 10.3390/ma15062230.
For some years now, fixation devices created with resorbable magnesium alloys for the mandibular head have been clinically available and are beginning to be used. It is thus valuable to evaluate the quality of unions in these cases. The aim of this study was radiological comparison of magnesium versus titanium open reduction and rigid fixations in the mandible condylar head. Thirty-one patients were treated for fractures of the mandibular head with magnesium WE43 alloy headless compression screws (diameter 2.3 mm) and, as a reference group, 29 patients were included with similar construction titanium screws (diameter 1.8 mm). The 12-month results of the treatment were evaluated by the texture analysis of CT. Near similar treatment results were found with magnesium screws in traditional titanium fixation. Magnesium screws result in a higher density of the bone structure in the mandibular head. Conclusions: The quantitative evaluation of bone union after surgical treatment of mandibular head fracture with magnesium compression headless screws indicates that stable consolidation was achieved. Undoubtedly, the resorption process of the screws was found to be incomplete after 12 months, evidenced by a marked densification of the bone structure at the fracture site.
近年来,用于下颌头的可吸收镁合金制成的固定装置已在临床上可用并开始得到应用。因此,评估这些病例中的骨愈合质量具有重要价值。本研究的目的是对镁合金与钛合金在下颌髁突头进行切开复位坚强内固定后的情况进行影像学比较。31例患者使用镁合金WE43无头加压螺钉(直径2.3mm)治疗下颌头骨折,作为参照组,纳入29例使用类似结构钛螺钉(直径1.8mm)的患者。通过CT纹理分析评估治疗12个月的结果。在传统钛固定中使用镁螺钉发现了近乎相似的治疗结果。镁螺钉在下颌头导致更高密度的骨结构。结论:用镁合金无头加压螺钉手术治疗下颌头骨折后对骨愈合的定量评估表明实现了稳定的骨痂形成。毫无疑问,12个月后发现螺钉的吸收过程不完全,骨折部位骨结构明显致密化证明了这一点。