Gated tomographic radionuclide angiography can assess and monitor left cardiac function. Dedicated cardiac CZT cameras have enabled dose reduction and quicker acquisitions. New 3D-ring CZT general purpose systems are now available. We report 50 patients who underwent a 7-minute acquisition on a cardiac-dedicated CZT camera and 9 minutes on a new 3D-ring CZT system after mean injection of 321.4 ± 55.9 MBq 99mTc-labelled human serum albumin. There was no significant difference in left ventricular volumes, and left and right ventricular ejection fractions. These preliminary results seem to validate the use of 3D-ring CZT system for LEVF and cardiac function evaluation.

摘要

门控断层放射性核素血管造影可评估和监测左心功能。专用心脏 CZT 相机可实现剂量减少和更快的采集。现在有新的 3D 环 CZT 通用系统。我们报告了 50 名患者,他们在专用 CZT 相机上进行了 7 分钟的采集,在新的 3D 环 CZT 系统上进行了 9 分钟的采集,平均注射 321.4±55.9MBq 99mTc 标记的人血清白蛋白。左心室容积、左心室和右心室射血分数无显著差异。这些初步结果似乎验证了 3D 环 CZT 系统用于左心室射血分数和心功能评估的应用。