Suppr超能文献

胰岛素药物制剂的放射受体测定法。

A radioreceptor assay for pharmaceutical preparations of insulin.

作者信息

Baxter D

出版信息

J Biol Stand. 1986 Oct;14(4):319-30. doi: 10.1016/0092-1157(86)90019-3.

Abstract

A radioreceptor assay has been developed that is suitable for the measurement of the potency of crystalline insulin and pharmaceutical insulin formulations. It utilizes the well characterized and widely available IM-9 human lymphocyte cell line as the source of receptor. Bovine, porcine and human crystalline and formulated insulins have been assayed against the 4th International and European Standards for Insulin and the potencies compared with those obtained by the mouse blood glucose method. Results with bovine insulin were in full correspondence with the in vivo results. Porcine and human insulins were 15-20% more potent by the radioreceptor assay than by the in vivo method when the mixed bovine and porcine insulin 4th International and European Standards were used, but were equivalent when compared with like materials. Average 95% confidence limits for formulated insulins in two assays were +/- 6% of the mean. The coefficient of variation on repeated assay of the same sample was 3.8%. The three dose parallel line radioreceptor assay with appropriate species species standards is a candidate biological test capable of international adoption as an alternative to in vivo animal testing of insulin.

摘要

已开发出一种放射受体测定法,适用于测定结晶胰岛素和药用胰岛素制剂的效价。它利用特性明确且广泛可得的IM - 9人淋巴细胞系作为受体来源。已针对第4版国际和欧洲胰岛素标准对牛、猪和人结晶胰岛素及制剂胰岛素进行了测定,并将效价与通过小鼠血糖法获得的效价进行了比较。牛胰岛素的结果与体内结果完全一致。当使用混合的牛和猪胰岛素第4版国际和欧洲标准时,放射受体测定法测得的猪和人胰岛素效价比体内法高15 - 20%,但与同类材料比较时则相当。两种测定法中制剂胰岛素的平均95%置信限为平均值的±6%。同一样品重复测定的变异系数为3.8%。采用适当种类标准的三剂量平行线放射受体测定法是一种有望被国际采用的生物试验,可替代胰岛素的体内动物试验。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验