CONTEXT

Newer glass ionomer cements with improved properties are constantly being developed. One such material is the novel Hybrid Glass-Ionomer cement (HGIC) with properties yet to be studied.

AIMS

The aim of this study was to compare the flexural strength, shear bond strength, wear resistance and fluoride release of Hybrid Glass Ionomer restorative with Conventional Glass Ionomer Cement (CGIC) and Resin modified Glass Ionomer Cement (RMGIC).

SETTINGS AND DESIGN

This was an in vitro study.

METHODS AND MATERIAL

A total of 300 samples were tested in this study, with 100 samples per group and each group was further subdivided into 5 sub-groups with 20 samples each. Flexural and Shear bond strength values were determined by subjecting the specimens to a universal testing machine. For wear resistance, the specimens were assessed using a pin on the disc tribometer. For fluoride release, the test specimen suspended in 10 mL deionised water was tested at 24 h and 1 week.

STATISTICAL ANALYSIS USED

One-way ANOVA.

RESULTS

RMGIC had the highest flexural and shear bond strength values followed by HGIC and CGIC. HGIC had the least wear rate followed by RMGIC and CGIC. At 24 h and 1 week, HGIC had the highest fluoride release among the study groups.

CONCLUSIONS

HGIC exhibited the highest wear resistance and fluoride release among the cements studied. However, flexural and Shear bond strength values, of RMGIC, was comparatively higher.

摘要

背景

新型玻璃离子水门汀具有不断改善的性能,正在不断被开发出来。其中一种新型材料是新型混合玻璃离子水门汀(HGIC),其性能有待研究。

目的

本研究旨在比较混合玻璃离子修复材料与传统玻璃离子水门汀(CGIC)和树脂改良玻璃离子水门汀(RMGIC)的弯曲强度、剪切粘结强度、耐磨性和氟释放。

设置和设计

这是一项体外研究。

方法和材料

本研究共测试了 300 个样本,每组 100 个样本,每个组进一步分为 5 个亚组,每个亚组 20 个样本。通过万能试验机对试件进行弯曲和剪切粘结强度值的测定。采用盘销磨损试验机对耐磨性进行评估。对氟释放的测试,将测试试件悬浮在 10ml 去离子水中,在 24 小时和 1 周时进行测试。

统计分析方法

单因素方差分析。

结果

RMGIC 的弯曲和剪切粘结强度值最高,其次是 HGIC 和 CGIC。HGIC 的磨损率最低,其次是 RMGIC 和 CGIC。在 24 小时和 1 周时,HGIC 是研究组中氟释放量最高的。

结论

HGIC 表现出研究中所有水门汀中最高的耐磨性和氟释放性。然而,RMGIC 的弯曲和剪切粘结强度值相对较高。