低水平很重要:桃过敏患者中低水平的Pru p 3 sIgE的临床相关性

Low Levels Matter: Clinical Relevance of Low Pru p 3 sIgE in Patients With Peach Allergy.

作者信息

Balsells-Vives Sara, San Bartolomé Clara, Casas-Saucedo Rocío, Ruano-Zaragoza María, Rius Josefina, Torradeflot Maria, Bartra Joan, Munoz-Cano Rosa, Pascal Mariona

机构信息

Clinical and Experimental Respiratory Immunoallergy (IRCE), Institut D'Investigacions Biomèdiques August Pi I Sunyer (IDIBAPS), Barcelona, Spain.

Department of Immunology, Centre de Diagnòstic Biomedic (CDB), Hospital Clínic de Barcelona, Barcelona, Spain.

出版信息

Front Allergy. 2022 Apr 5;3:868267. doi: 10.3389/falgy.2022.868267. eCollection 2022.

Abstract

Many clinical lab settings still use 0.35 KU/L as the cut-off for serum specific-IgE (sIgE) immunoassays, while the detection limit is 0.1 KU/L. The clinical relevance of -low-level sIgE (0.1-0.35 KU/L) remains controversial. Pru p 3 sIgE is considered to be the main routine tool for assessing lipid transfer protein (LTP) sensitization. We aimed to evaluate the clinical relevance of Pru p 3 sIgE low levels in a population diagnosed with LTP allergy. Adults diagnosed with LTP allergy and Pru p 3 sIgE ≥ 0.1 KUA/L between 2012 and 2019 were included. Clinical data were reviewed. nPru p 3 basophil activation test (BAT) was performed and basophil reactivity (BR) and sensitivity (BS) correlated with the peach allergy symptoms. Pru p 3 sIgE from 496 subjects was recorded, 114 (23.0%) between 0.1 and 0.34 KU/L (grLOW), the rest ≥ 0.35 KU/L (grB). A total of 44.7% in grLOW and 59.9% in grB were allergic. Urticaria was more frequent in grLOW. In grLOW, Pru p 3 sIgE was higher in patients with local compared with systemic symptoms. In grB, Pru p 3 sIgE was higher in allergic patients. Pru p 3/Total IgE ratios were higher in allergic vs. tolerant in both groups. In BAT, BR was similar in both groups. In grLOW, it was higher on allergic compared with tolerant ( = 0.0286), and on those having systemic vs. local symptoms ( = 0.0286). BS showed no significant difference between groups. Patients with low levels represent a non-negligible fraction and around 45% are peach allergic. BAT showed functional sIgE in them. Pru p 3 sensitizations should be carefully evaluated even when sIgE levels are low.

摘要

许多临床实验室仍将0.35 KU/L作为血清特异性IgE(sIgE)免疫测定的临界值,而检测限为0.1 KU/L。低水平sIgE(0.1 - 0.35 KU/L)的临床相关性仍存在争议。Pru p 3 sIgE被认为是评估脂质转移蛋白(LTP)致敏的主要常规工具。我们旨在评估在诊断为LTP过敏的人群中Pru p 3 sIgE低水平的临床相关性。纳入了2012年至2019年间诊断为LTP过敏且Pru p 3 sIgE≥0.1 KUA/L的成年人。回顾了临床数据。进行了nPru p 3嗜碱性粒细胞活化试验(BAT),并将嗜碱性粒细胞反应性(BR)和敏感性(BS)与桃子过敏症状相关联。记录了496名受试者的Pru p 3 sIgE,其中114名(23.0%)在0.1至0.34 KU/L之间(grLOW),其余≥0.35 KU/L(grB)。grLOW组中44.7%、grB组中59.9%有过敏反应。grLOW组中荨麻疹更常见。在grLOW组中,有局部症状的患者Pru p 3 sIgE高于有全身症状的患者。在grB组中,过敏患者的Pru p 3 sIgE更高。两组中过敏患者的Pru p 3/总IgE比值均高于耐受患者。在BAT中,两组的BR相似。在grLOW组中,过敏患者的BR高于耐受患者(P = 0.0286),有全身症状患者的BR高于有局部症状患者(P = 0.0286)。两组之间BS无显著差异。低水平sIgE的患者占不可忽视的比例,约45%对桃子过敏。BAT显示他们体内存在功能性sIgE。即使sIgE水平较低,也应仔细评估Pru p 3致敏情况。