Department of Ophthalmology, Graduate School of Medicine, Osaka University, Osaka, Japan.
Hawaii Macula and Retina Institute, Aiea, HI, USA.
Transl Vis Sci Technol. 2022 Jul 8;11(7):1. doi: 10.1167/tvst.11.7.1.
Intrachoroidal cavitations (ICCs) are peripapillary pathological lesions generally associated with high myopia that can cause visual field (VF) defects. The current study aimed to evaluate a three-dimensional (3D) volume parameter of ICCs segmented from volumetric swept-source optical coherence tomography (SS-OCT) images processed using deep learning (DL)-based noise reduction and to investigate its correlation with VF sensitivity.
Thirteen eyes of 12 consecutive patients with peripapillary ICCs were enrolled. DL-based denoising and further analyses were applied to parapapillary 6 × 6-mm volumetric SS-OCT scans. Then, 3D ICC volume and two-dimensional depth and length measurements of the ICCs were calculated. The correlations between ICC parameters and VF sensitivity were investigated.
The ICCs were located in the inferior hemiretina in all eyes. ICC volume (P = 0.02; regression coefficient [RC], -0.007) and ICC length (P = 0.04; RC, -4.51) were negatively correlated with the VF mean deviation, whereas ICC depth (P = 0.15) was not. All of the parameters, including ICC volume (P = 0.01; RC, -0.004), ICC depth (P = 0.02; RC, -0.008), and ICC length (P = 0.045; RC, -2.11), were negatively correlated with the superior mean total deviation.
We established the volume of ICCs as a new 3D parameter, and it reflected their influence on visual function. The automatic delineation and 3D rendering may lead to improved detection and pathological understanding of ICCs.
This study demonstrated the correlation between the 3D volume of ICCs and VF sensitivity.
脉络膜内空洞(ICCs)是一种位于视盘周围的病理性病变,通常与高度近视有关,可导致视野(VF)缺损。本研究旨在评估一种从基于深度学习(DL)降噪处理的容积扫频源光学相干断层扫描(SS-OCT)图像中分割 ICCs 的三维(3D)体积参数,并研究其与 VF 敏感性的相关性。
纳入 12 例连续患者的 13 只眼,这些患者均存在视盘周围 ICCs。对视盘旁 6×6mm 容积 SS-OCT 扫描进行基于 DL 的降噪和进一步分析。然后,计算 ICC 的 3D ICC 体积和二维深度及长度测量值。研究 ICC 参数与 VF 敏感性之间的相关性。
所有患者的 ICC 均位于下方半视网膜。ICCV (P=0.02;回归系数[RC],-0.007)和 ICC 长度(P=0.04;RC,-4.51)与 VF 平均偏差呈负相关,而 ICC 深度(P=0.15)则没有。所有参数,包括 ICC 体积(P=0.01;RC,-0.004)、ICC 深度(P=0.02;RC,-0.008)和 ICC 长度(P=0.045;RC,-2.11),与上侧平均总偏差呈负相关。
我们建立了 ICCs 的体积作为新的 3D 参数,反映了它们对视功能的影响。自动勾画和 3D 渲染可能会提高 ICCs 的检测和病理认识。
翻译是否准确?