Deng Ming-Hui, Wang Xiao-Gang, Chen Song, Shi Xue-Feng
Clinical College of Ophthalmology, Tianjin Medical University, Tianjin 300070, China.
Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin Eye Hospital, Tianjin 300020, China.
Int J Ophthalmol. 2022 Jun 18;15(6):924-931. doi: 10.18240/ijo.2022.06.09. eCollection 2022.
To investigate the binocular intraocular lens (IOL) power difference in eyes with short, normal, and long axial lengths (AL) using Lenstar LS 900 optical biometry.
A total of 716 (1432 eyes) participants were included. The groups were categorized into short (group A: AL<22 mm), normal (group B: 22 mm≤AL≤25 mm), and long AL groups (group C: AL>25 mm). The central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), AL, anterior corneal keratometry, white-to-white (WTW), pupil diameter (PD), as well as IOL power calculated using embedded Barrett formula were assessed. Bland-Altman plots were used to test the agreement of the binocular parameters.
In group A, the CCT of the right eye was significantly thinner than that of the left eye (=0.044) with a difference of -2±8 µm [95% limits of agreement (LoA), -17.8 to 13.2 µm]. For group B, the PD and IOL power in the right eye were significantly lower than those of the left eye (=0.001, <0.001) with a difference of -0.05±0.32 mm (95%LoA, -0.68 to 0.58 mm) and -0.18±1.01 D (95%LoA, -2.2 to 1.8 D). The AL of right eye was longer than that of the left eye (=0.002) with a difference of 0.04±0.25 mm (95%LoA, -0.45 to 0.52 mm). No significant difference was observed for all the binocular parameters in group C. The percentage of participants with binocular IOL power difference within ±0.5 D were 62% (31/50), 68.3% (339/496), and 38.8% (66/170) in groups A, B, and C, respectively.
The binocular parameters related to IOL power are in good agreement, but the binocular IOL power difference of more than half of participants with long AL is more than 0.50 D.
使用Lenstar LS 900光学生物测量仪研究眼轴短、正常和长的眼睛的双眼人工晶状体(IOL)屈光度差异。
共纳入716名(1432只眼)参与者。这些组被分为眼轴短组(A组:眼轴<22mm)、正常组(B组:22mm≤眼轴≤25mm)和眼轴长组(C组:眼轴>25mm)。评估中央角膜厚度(CCT)、前房深度(ACD)、晶状体厚度(LT)、眼轴、前角膜曲率、白对白(WTW)、瞳孔直径(PD),以及使用内置的巴雷特公式计算的IOL屈光度。采用Bland-Altman图检验双眼参数的一致性。
在A组中,右眼的CCT明显比左眼薄(P=0.044),差值为-2±8μm[95%一致性界限(LoA),-17.8至13.2μm]。在B组中,右眼的PD和IOL屈光度明显低于左眼(P=0.001,P<0.001),差值分别为-0.05±0.32mm(95%LoA,-0.68至0.58mm)和-0.18±1.01D(95%LoA,-2.2至1.8D)。右眼的眼轴比左眼长(P=0.002),差值为0.04±0.25mm(95%LoA,-0.45至0.52mm)。C组所有双眼参数均未观察到显著差异。A组、B组和C组中双眼IOL屈光度差值在±0.5D以内的参与者百分比分别为62%(31/50)、68.3%(339/496)和38.8%(66/170)。
与IOL屈光度相关的双眼参数一致性良好,但超过一半的眼轴长参与者的双眼IOL屈光度差值大于0.50D。