Nagano Prefecture General Industrial Technology Center, Nagano, Japan.
National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan.
Med Biol Eng Comput. 2022 Oct;60(10):2825-2840. doi: 10.1007/s11517-022-02590-4. Epub 2022 Jul 26.
Variability in swallowing electromyography (EMG) has been reported to occur due to individual differences, even in studies with appropriate control of factors affecting EMG such as food type, properties, and posture. The increased variability broadens the confidence intervals of measures obtained from EMG, such as time and amplitude, and makes it difficult to detect differences in muscle activity. This makes it impossible to detect slight changes in swallowing function at an early stage, which is required for clinical examination. In this study, we focused on the tipper type and dipper type of oral swallows, which differ in the timing of muscle activity. The frequency of occurrence of both types varies between participants, and both types could occur in the same participant. In this study, we measured swallowing EMG wherein participants were instructed to swallow with a tipper and a dipper. The results showed that there was a significant difference in the between-participant duration between these two types of swallows. Within-participant variability was significantly lower in the tipper-dipper instruction condition compared to the baseline condition, which assumed a mixture of tipper-dipper swallowing. These results demonstrate that instructions on swallowing method are effective in improving the reproducibility of EMG.
吞咽肌电图(EMG)的变异性已被报道是由于个体差异所致,即使在对影响 EMG 的因素(如食物类型、特性和姿势)进行适当控制的研究中也是如此。变异性的增加扩大了从 EMG 获得的测量值(如时间和幅度)的置信区间,使得难以检测肌肉活动的差异。这使得无法在临床检查中早期检测到吞咽功能的微小变化。在这项研究中,我们专注于口腔吞咽的 tipper 型和 dipper 型,它们在肌肉活动的时间上有所不同。两种类型的发生频率在参与者之间有所不同,并且同一参与者可能同时存在这两种类型。在这项研究中,我们测量了吞咽 EMG,其中要求参与者使用 tipper 和 dipper 进行吞咽。结果表明,这两种吞咽类型之间的参与者间持续时间存在显著差异。与假设 tipper-dipper 吞咽混合的基线条件相比,tipper-dipper 指令条件下的个体内变异性显著降低。这些结果表明,吞咽方法的指导在提高 EMG 的可重复性方面是有效的。