Quantitative evaluation of the human corneal grafts stored in the tissue banks is usually limited to endothelial cell density and central thickness. Swept-source OCT (SS-OCT) is capable of measuring the central curvatures of the corneal tissue prepared for transplantation without loss of sterileness, providing insights on its refractive state. The aim of the paper is to compare in vitro SS-OCT measurements with pre-excision values. Hand-held keratometry and ultrasound pachymetry was performed on 22 corneas before excision of corneoscleral button and insertion in the vial with Eusol-C solution (AlchimiaS.r.l, Nicolò, Italy). After 12 to 36 h of hypothermic storage the corneas were examined within the vials with custom built SS-OCT system maintaining a sterile environment. The anterior and posterior central curvatures, and central corneal thickness (CCT) were measured. Rotation of the corneoscleral button was controlled by making a 6-o'clock mark during excision. Mean pre-excision CCT was 626.45 ± 28.71 µm and 468.05 ± 52.96 µm when measured with SS OCT (r = 0.55; p < 0.001). Respective values for average keratometry were 7.74 ± 0.39 mm and 7.92 ± 0.57 mm (r = 0.6; p = 0.22). Although high differences were observed in corneal thickness, keratometric radius of curvature at the flat (r = 0.42; p < 0.001) and steep (r = 0.62; p = 0.014) meridian of the anterior corneal surface, as well as corneal anterior astigmatism (r = 0.3; p < 0.001), showed good correlation with pre-excision values. SS-OCT is capable of providing quantitative evaluation of the human corneal grafts in hypothermic storage. Good correlation between curvature measurements before excision and during banking in the vial indicates its clinical utility.
定量评估保存在组织库中的人角膜移植物通常仅限于内皮细胞密度和中央厚度。扫频源光学相干断层扫描(SS-OCT)能够在不丧失无菌性的情况下测量准备移植的角膜组织的中央曲率,提供其屈光状态的见解。本文的目的是比较体外 SS-OCT 测量值与术前值。在切除角膜巩膜瓣并插入含 Eusol-C 溶液的小瓶(意大利 AlchimiaS.r.l 公司生产的 Nicolò)之前,对 22 个角膜进行手持角膜曲率计和超声测厚检查。在低温保存 12 至 36 小时后,在保持无菌环境的情况下,使用定制的 SS-OCT 系统在小瓶内检查角膜。测量前、后中央曲率和中央角膜厚度(CCT)。在切除时做一个 6 点钟标记来控制角膜巩膜瓣的旋转。术前 CCT 的平均值为 626.45 ± 28.71 µm,用 SS-OCT 测量时为 468.05 ± 52.96 µm(r = 0.55;p < 0.001)。平均角膜曲率计的相应值为 7.74 ± 0.39 mm 和 7.92 ± 0.57 mm(r = 0.6;p = 0.22)。尽管角膜厚度存在较大差异,但角膜前表面平坦(r = 0.42;p < 0.001)和陡峭(r = 0.62;p = 0.014)子午线的曲率半径以及角膜前散光(r = 0.3;p < 0.001)与术前值有很好的相关性。SS-OCT 能够对低温保存的人角膜移植物进行定量评估。切除前和小瓶内保存期间的曲率测量之间具有良好的相关性,表明其具有临床应用价值。