Calvo-Ortega Juan-Francisco, Greer Peter B, Moragues-Femenía Sandra, Pozo-Massó Miguel, Casals-Farran Joan
Servicio de Oncología Radioterápica, Hospital Quirónsalud Barcelona, Barcelona, Spain.
Department of Radiation Oncology, Calvary Mater Newcastle Hospital, Newcastle, Australia.
Rep Pract Oncol Radiother. 2022 Jul 29;27(3):449-457. doi: 10.5603/RPOR.a2022.0042. eCollection 2022.
The purpose of this study was to describe the use of the VIPER software for patient-specific quality assurance (PSQA) of single-isocenter multitarget (SIMT) stereotactic radiosurgery (SRS) plans.
Twenty clinical of intensity-modulated (IMRT) SIMT SRS plans were reviewed. A total of 88 brain metastases were included. Number of lesions per plan and their individual volumes ranged from 2 to 35 and from 0.03 to 32.8 cm, respectively. Plans were designed with the Eclipse system, and delivered using a Varian CLINAC linac. SRS technique consisted of non-coplanar static-field sliding-window IMRT. Each plan was mapped onto a virtual cylindrical water phantom (VCP) in the Eclipse to calculate a 3D dose distribution (verification plan). The VIPER software reconstructed the 3D dose distribution inside the VCP from the acquired in-air electronic portal image device (EPID) images of the treatment fields. A 3D gamma analysis was used to compare the reconstructed doses to the Eclipse planned doses on the VCP. Gamma passing rates (GPRs) were calculated using 3% global/2 mm criteria and dose thresholds ranged from 10% to 90% of the maximum dose.
The averages (± 1 SD) of the 3D GPRs over the 20 SRS plans were: 99.9 ± 0.2%, 99.7 ± 0.3%, 99.6 ± 0.5%, 99.3 ± 0.9%,99.1 ± 1.6%, 99.0 ± 1.6%, and 98.5 ± 3.3%, for dose thresholds of 10%, 20%, 30%, 50%, 70%, 80% and 90% respectively.
This work shows the feasibility of the VIPER software for PSQA of SIMT SRS plans, being a reliable alternative to commercially available 2D detector arrays.
本研究的目的是描述使用VIPER软件对单中心多靶点(SIMT)立体定向放射外科(SRS)计划进行患者特异性质量保证(PSQA)的情况。
回顾了20例调强(IMRT)SIMT SRS计划的临床病例。共纳入88个脑转移瘤。每个计划中的病灶数量及其个体体积分别为2至35个和0.03至32.8 cm³。计划使用Eclipse系统设计,并使用瓦里安CLINAC直线加速器进行治疗。SRS技术包括非共面静态野滑动窗口IMRT。每个计划被映射到Eclipse中的虚拟圆柱形水模体(VCP)上,以计算三维剂量分布(验证计划)。VIPER软件根据采集的治疗野的空中电子门静脉成像设备(EPID)图像重建VCP内的三维剂量分布。使用三维伽马分析将重建剂量与Eclipse在VCP上计划的剂量进行比较。伽马通过率(GPR)使用3%全局/2 mm标准计算,剂量阈值范围为最大剂量的10%至90%。
20个SRS计划的三维GPR平均值(±1标准差)分别为:剂量阈值为10%时,99.9±0.2%;20%时,99.7±0.3%;30%时,99.6±0.5%;50%时,99.3±0.9%;70%时,99.1±1.6%;80%时,99.0±1.6%;90%时,98.5±3.3%。
这项工作表明VIPER软件用于SIMT SRS计划的PSQA是可行的,是市售二维探测器阵列的可靠替代方案。