Suppr超能文献

热塑性聚氨酯和明胶共混纳米纤维覆膜支架在猪髂动脉中的疗效。

Efficacy of thermoplastic polyurethane and gelatin blended nanofibers covered stent graft in the porcine iliac artery.

机构信息

Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Republic of Korea.

Department of Mechanical Engineering, Sejong University, 209, Neungdong-ro, Gwangjin-gu, Seoul, 05006, Republic of Korea.

出版信息

Sci Rep. 2022 Oct 3;12(1):16524. doi: 10.1038/s41598-022-20950-w.

Abstract

Stent-grafts composed of expanded polytetrafluoroethylene (e-PTFE), polyethylene terephthalate (PET) and polyurethane (PU) are characterized by poor endothelialization, high modulus, and low compliance, leading to thrombosis and intimal hyperplasia. A composite synthetic/natural matrix is considered a promising alternative to conventional synthetic stent-grafts. This study aimed to investigate the efficacy of thermoplastic polyurethane (TPU) and gelatin (GL) blended nanofibers (NFs) covered stent-graft in the porcine iliac artery. Twelve pigs were randomly sacrificed 7 days (n = 6) and 28 days (n = 6) after stent-graft placement. The thrombogenicity score at 28 days was significantly increased compared at 7 days (p < 0.001). The thickness of neointimal hyperplasia, degree of inflammatory cell infiltration, and degree of collagen deposition were significantly higher at 28 days than at 7 days (all p < 0.001). The TPU and GL blended NFs-covered stent-grafts successfully maintained the patency for 28 days in the porcine iliac artery. Although thrombosis with neointimal tissue were observed, no subsequent occlusion of the stent-graft was noted until the end of the study. Composite synthetic/natural matrix-covered stent-grafts may be promising for prolonging stent-graft patency.

摘要

由膨化聚四氟乙烯(e-PTFE)、聚对苯二甲酸乙二醇酯(PET)和聚氨酯(PU)组成的支架移植物的特点是内皮化不良、模量高、顺应性低,导致血栓形成和内膜增生。复合合成/天然基质被认为是传统合成支架移植物的一种有前途的替代物。本研究旨在研究热塑性聚氨酯(TPU)和明胶(GL)混合纳米纤维(NFs)覆盖的支架移植物在猪髂动脉中的疗效。12 只猪随机在支架植入后 7 天(n=6)和 28 天(n=6)处死。28 天时的血栓形成评分明显高于 7 天时(p<0.001)。28 天时的新生内膜增生厚度、炎症细胞浸润程度和胶原沉积程度均明显高于 7 天时(均 p<0.001)。TPU 和 GL 混合 NFs 覆盖的支架移植物在猪髂动脉中成功维持了 28 天的通畅。尽管观察到血栓形成和新生内膜组织,但在研究结束前没有发现支架移植物随后闭塞。复合合成/天然基质覆盖的支架移植物可能有望延长支架移植物的通畅时间。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/c256/9529973/c494fbe52ee4/41598_2022_20950_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验