R&D Center, Ray, Seongnam-si 13494, Republic of Korea.
Department of Biomedical Engineering, Kyung Hee University, Yongin-si 17104, Republic of Korea.
Sensors (Basel). 2023 Jan 23;23(3):1288. doi: 10.3390/s23031288.
Metal artifacts in dental computed tomography (CT) images, caused by highly X-ray absorbing objects, such as dental implants or crowns, often more severely compromise image readability than in medical CT images. Since lower tube voltages are used for dental CTs in spite of the more frequent presence of metallic objects in the patient, metal artifacts appear more severely in dental CT images, and the artifacts often persist even after metal artifact correction. The direct sinogram correction (DSC) method, which directly corrects the sinogram using the mapping function derived by minimizing the sinogram inconsistency, works well in the case of mild metal artifacts, but it often fails to correct severe metal artifacts. We propose a modified DSC method to reduce severe metal artifacts, and we have tested it on human dental images. We first segment the metallic objects in the CT image, and then we forward-project the segmented metal mask to identify the metal traces in the projection data with computing the metal path length for the rays penetrating the metal mask. In the sinogram correction with the DSC mapping function, we apply the weighting proportional to the metal path length. We have applied the proposed method to the phantom and patient images taken at the X-ray tube voltage of 90 kVp. We observed that the proposed method outperforms the original DSC method when metal artifacts were severe. However, we need further extensive studies to verify the proposed method for various CT scan conditions with many more patient images.
牙科计算机断层扫描(CT)图像中的金属伪影是由高度吸收 X 射线的物体引起的,例如牙种植体或牙冠,这些伪影通常比医学 CT 图像更严重地影响图像可读性。由于牙科 CT 中使用的管电压较低,尽管患者中金属物体更常见,但牙科 CT 图像中的金属伪影更为严重,即使经过金属伪影校正后,伪影仍然存在。直接正弦图校正(DSC)方法通过最小化正弦图不一致性来直接使用映射函数校正正弦图,在轻度金属伪影的情况下效果很好,但在严重金属伪影的情况下往往无法校正。我们提出了一种改进的 DSC 方法来减少严重的金属伪影,并在人体牙科图像上进行了测试。我们首先对 CT 图像中的金属物体进行分割,然后向前投影分割的金属掩模,以通过计算穿透金属掩模的射线的金属路径长度来识别投影数据中的金属痕迹。在使用 DSC 映射函数的正弦图校正中,我们应用与金属路径长度成比例的权重。我们已经将提出的方法应用于在 90 kVp 管电压下拍摄的幻影和患者图像。我们观察到,当金属伪影严重时,该方法优于原始 DSC 方法。然而,我们需要进一步进行广泛的研究,以验证该方法在具有更多患者图像的各种 CT 扫描条件下的有效性。