超声测量股四头肌厚度的可靠性和有效性:与肌肉质量和力量的比较

Reliability and Validity of Quadriceps Muscle Thickness Measurements in Ultrasonography: A Comparison with Muscle Mass and Strength.

作者信息

Ogawa Masato, Matsumoto Tsuyoshi, Harada Risa, Yoshikawa Ryo, Ueda Yuya, Takamiya Daiki, Sakai Yoshitada

机构信息

Division of Rehabilitation Medicine, Kobe University Hospital, Kobe, Japan.

Department of Public Health, Kobe University Graduate School of Health Sciences, Kobe, Japan.

出版信息

Prog Rehabil Med. 2023 Mar 11;8:20230008. doi: 10.2490/prm.20230008. eCollection 2023.

Abstract

OBJECTIVES

Measurement of skeletal muscle using ultrasonography (US) has received considerable attention as an alternative method of muscle assessment. However, intra- and inter-rater reliability remains controversial. Furthermore, there is no consensus regarding the relationship between muscle assessment using US and muscle mass or physical assessment. We aimed to verify the validity and reliability of muscle measurements using US and its relationships with muscle strength and physical assessment.

METHODS

The 22 participants were all healthy men. Quadriceps muscle thickness was measured by US by three different raters. Intraclass correlation coefficient (ICC) was used to assess inter- and intra-rater reliability. The maximum isokinetic strength of the quadriceps and handgrip strength were used as measures of lower and upper muscle strength, respectively. Leg muscle mass was assessed using the leg skeletal muscle index (SMI), measured by body impedance analysis, and calf circumference.

RESULTS

The intra-rater reliability was excellent which the ICC(1,1) ranges 0.957-0.993, and ICC(1,3) ranges 0.985-0.998. For inter-rater reliability, the values of 0.904 for ICC(2,1) and 0.966 for ICC(2,3) indicated excellent reliability. Leg SMI was significantly correlated with quadriceps thickness (r=0.36). Maximum isokinetic strength and handgrip strength showed weak but statistically significant correlations with quadriceps thickness (r=0.20, r=0.30, respectively). The correlation between quadriceps thickness and calf circumference was not statistically significant.

CONCLUSIONS

Quadriceps muscle assessment using US is a valid and reliable technique for healthy individuals. Quadriceps muscle thickness was significantly positively correlated with upper and lower muscle strength and leg SMI. Muscle thickness assessment could replace full body muscle assessment in clinical settings.

摘要

目的

使用超声(US)测量骨骼肌作为肌肉评估的替代方法已受到广泛关注。然而,评估者内和评估者间的可靠性仍存在争议。此外,关于使用US进行肌肉评估与肌肉质量或身体评估之间的关系尚无共识。我们旨在验证使用US进行肌肉测量的有效性和可靠性及其与肌肉力量和身体评估的关系。

方法

22名参与者均为健康男性。由三名不同的评估者使用US测量股四头肌厚度。组内相关系数(ICC)用于评估评估者间和评估者内的可靠性。股四头肌的最大等速力量和握力分别用作下肢和上肢肌肉力量的指标。使用通过身体阻抗分析测量的腿部骨骼肌指数(SMI)和小腿围来评估腿部肌肉质量。

结果

评估者内可靠性极佳,ICC(1,1)范围为0.957 - 0.993,ICC(1,3)范围为0.985 - 0.998。对于评估者间可靠性,ICC(2,1)为0.904,ICC(2,3)为0.966,表明可靠性极佳。腿部SMI与股四头肌厚度显著相关(r = 0.36)。最大等速力量和握力与股四头肌厚度呈弱但具有统计学意义的相关性(分别为r = 0.20,r = 0.30)。股四头肌厚度与小腿围之间的相关性无统计学意义。

结论

对于健康个体,使用US评估股四头肌是一种有效且可靠的技术。股四头肌厚度与上肢和下肢肌肉力量以及腿部SMI显著正相关。在临床环境中,肌肉厚度评估可替代全身肌肉评估。