Department of Radiology, Gachon University College of Medicine, Gil Medical Center, Incheon, South Korea.
Department of Surgery, Gachon University College of Medicine, Incheon, South Korea.
Diagn Interv Radiol. 2023 Jan 31;29(1):175-182. doi: 10.5152/dir.2022.21551. Epub 2022 Dec 21.
To investigate the image quality of lower extremity computed tomography angiography (LE-CTA) using a reconstruction algorithm for monoenergetic images (MEIs) to evaluate peripheral arterial disease (PAD) at different kiloelectron volt (keV) levels.
A total of 146 consecutive patients who underwent LE-CTA on a dual-energy scanner to obtain MEIs at 40, 50, 60, 70, and 80 keV were included. The overall image quality, segmental image quality of the arteries and PAD segments, venous contamination, and metal artifacts from prostheses, which may compromise quality, were analyzed.
The mean overall image quality of each MEI was 2.9 ± 0.7, 3.6 ± 0.6, 3.9 ± 0.3, 4.0 ± 0.2, and 4.0 ± 0.2 from 40 to 80 keV, respectively. The segmental image quality gradually increased from 40 to 70-80 keV until reaching its highest value. Among 295 PAD segments in 68 patients, 40 (13.6%) were scored at 1-2 at 40 keV and 13 (4.4%) were scored at 2 at 50 keV, indicating unsatisfactory image quality due to the indistinguishability between high-contrast areas and arterial calcifications. The segments exhibiting metal artifacts and venous contamination were reduced at 70-80 keV (2.6 ± 1.2, 2.7 ± 0.5) compared with at 40 keV (2.4 ± 1.1, 2.5 ± 0.7).
The LE-CTA method using a reconstruction algorithm for MEIs at 70-80 keV can enhance the image quality for PAD evaluation and improve mitigate venous contamination and metal artifacts.
利用单能量图像(MEI)重建算法研究下肢 CT 血管造影(LE-CTA)的图像质量,以评估不同千电子伏特(keV)水平的外周动脉疾病(PAD)。
共纳入 146 例连续接受双能扫描仪进行 LE-CTA 以获取 40、50、60、70 和 80keV 的 MEI 的患者。分析了整体图像质量、动脉和 PAD 节段的节段图像质量、静脉污染以及可能影响质量的假体金属伪影。
40 至 80keV 时,每个 MEI 的平均整体图像质量分别为 2.9±0.7、3.6±0.6、3.9±0.3、4.0±0.2 和 4.0±0.2。节段图像质量从 40keV 逐渐增加到 70-80keV,直到达到最高值。在 68 例患者的 295 个 PAD 节段中,40keV 时有 40 个(13.6%)评分为 1-2,50keV 时有 13 个(4.4%)评分为 2,表明图像质量不佳,因为高对比度区域和动脉钙化之间难以区分。与 40keV 时相比,70-80keV 时显示金属伪影和静脉污染的节段减少(2.6±1.2、2.7±0.5)。
使用 70-80keV 的 MEI 重建算法的 LE-CTA 方法可以提高 PAD 评估的图像质量,并减轻静脉污染和金属伪影的影响。